M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
34
IB-1501279-H
Details
When the NC reset signal is input with the High-speed simple program check: Coordinate position check ON
signal (Y76B) set to ON, the machine coordinate position is different from the position at the program start.
Remedy
Correct the machining program.
Details
The following operation was performed to an axis which can be switched over between NC axis and PLC axis.
PLC axis switchover signal was turned ON or OFF when it was prohibited to switch over the axis.
Remedy
Make sure the axis switchover status signal is OFF and change the ON/OFF of the axis switchover signal.
Details
You have set the R register for selecting synchronous control operation method, although the option of multiple
axis synchronization control is OFF.
Remedy
Set 0 in R2589 (Synchronous control operation method selection).
Details
For the multiple axis synchronization control, you selected two or more slave axes without selecting any master
axis.
Remedy
Correct the setting of R2589 (Synchronous control operation method selection).
Details
A command has been given that causes two or more objects to interfere with each other.
yy : Interference object definition number (1)
zz : Interference object definition number (2)
Remedy
Cancel the alarm with reset.
Disable the interference check III mode first before moving the interfering object further in the interference
direction.
Details
Two or more interfering objects are in the interference alarm area.
yy : Interference object definition number (1)
zz : Interference object definition number (2)
Remedy
Disable the interference check III mode before moving.
Check the interference definition and the interference selection.
Details
A command has been given that causes two or more interfering objects to enter the interference warning area.
yy : Interference object definition number (1)
zz : Interference object definition number (2)
Remedy
Interfering objects are in the interference warning area.
If an operational problem is expected to occur, stop moving the axes with feed hold, cancellation of manual axis
movement or reset.
M01
Prog check: machine posn error
1216
M01
NC/PLC axis switch illegal
1250
M01
No spec: Multi axis synch ctrl
1254
M01
Multiple secondary ax selected
1255
M03
Interference detection
0001
yyzz
M03
Entry in interfere alarm area
0002
yyzz
M03
Entry in interfere warn area
0003
yyzz
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......