M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
553
IB-1501279-H
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when gear 01
is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of slim-
it2(#3002) to tapt32(#3046).
---Setting range---
1 to 5000 (ms)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when gear 10
is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of slim-
it3(#3003) to tapt33(#3047).
---Setting range---
1 to 5000 (ms)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when gear 11
is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of slim-
it4(#3004) to tapt34(#3048).
---Setting range---
1 to 5000 (ms)
Set the acceleration/deceleration time constant under spindle synchronization control.
The inclination of acceleration/deceleration control is determined by the ratio to limit rotation speed (slimit).
Set the same value for the reference axis and synchronous axis.
The time constant for 2nd step or subsequent steps is the magnification setting on the basis of this setting
value.
---Setting range---
0 to 9999 (ms)
Set the level of speed difference between the basic and synchronous spindles during spindle synchronization
control. Setting of the synchronous spindle side is enabled. When the difference becomes below the setting
level, the spindle speed synchronization complete signal will turn ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
Set the level of phase difference between the basic and synchronous spindles during spindle synchroniza-
tion. Setting of the synchronous spindle side is validated. When the difference becomes below the setting
level, the spindle phase synchronization complete signal will go ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
Set the polarity to match the rotation direction between the spindles which perform synchronization control
under spindle synchronization control.
0: Positive polarity (Spindle CW rotation at motor CW rotation)
1: Negative polarity (Spindle CCW rotation at motor CW rotation)
---Setting range---
0000/0001 (HEX)
#3046
tapt32
Synchronous tapping 3rd step acceleration/decelera-
tion time constant (Gear: 01)
#3047
tapt33
Synchronous tapping 3rd step acceleration/decelera-
tion time constant (Gear: 10)
#3048
tapt34
Synchronous tapping 3rd step acceleration/decelera-
tion time constant (Gear: 11)
#3049
spt
Spindle synchronization acceleration/deceleration time
constant
#3050
sprlv
Spindle synchronization rotation speed attainment lev-
el
#3051
spplv
Spindle phase synchronization attainment level
#3052
spplr
Spindle synchronization relative polarity
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......