M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
555
IB-1501279-H
Set the speed which switches from 7th step to 8th step in spindle synchronization multi-step acceleration/
deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 1 (sptc1) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 2 (sptc2) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 3 (sptc3) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 4 (sptc4) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 5 (sptc5) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 6 (sptc6) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
Set the acceleration/deceleration time constant to be used at the speed of changeover speed 7 (sptc7) and
higher in spindle synchronization multi-step acceleration/deceleration control. Set this as a magnification in
relation to the spindle synchronization acceleration/deceleration time constant (spt).
---Setting range---
0 to 127
#3060
sptc7
Spindle synchronization multi-step acceleration/decel-
eration changeover speed 7
#3061
spdiv1
Time constant magnification for changeover speed 1
#3062
spdiv2
Time constant magnification for changeover speed 2
#3063
spdiv3
Time constant magnification for changeover speed 3
#3064
spdiv4
Time constant magnification for changeover speed 4
#3065
spdiv5
Time constant magnification for changeover speed 5
#3066
spdiv6
Time constant magnification for changeover speed 6
#3067
spdiv7
Time constant magnification for changeover speed 7
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......