M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
559
IB-1501279-H
bit8: Designate zero point return
0: Compatible operation with our conventional series (Automatically return to zero point simultaneously with
C-axis changeover)
1: Standard setting
bit7: Synchronous tapping command polarity
0: Forward direction
1: Reverse direction (The standard setting when spindle and motor are directly coupled)
bit6-5: Synchronous tapping zero point return direction
bit 6,5=
00: Short-cut
01: Forward run
10: Reverse run
bit4: Designate zero point return
0: Automatically return to zero point before synchronous tapping is started (tapping phase alignment)
1: Not return to zero point and immediately synchronous tapping is started
bit3: Z phase detection operation ON
0: When Z phase is not detected, detect Z phase during the rotation executed by a rotation command with-
out performing the detection operation.
1: When Z phase is not detected, perform the detection operation according to the settings of bitC and bit0,
and then rotate the motor according to a rotation command.
bit2-1: Orientation direction
bit 2,1=
00: Short-cut
01: Forward run
10: Reverse run
bit0: Z phase detection direction
0: Forward direction
1: Reverse direction
Set the spindle speed during orientation command.
When the spindle is not running or running to the different direction with the orientation, the orientation is car-
ried out with this speed after a stop. When the spindle is running to the same direction with the orientation,
this parameter does not have a meaning because it decelerates directly and the orientation is carried out.
---Setting range---
1 to 99999 (r/min)
The orientation stop position can be moved by this parameter setting although normally the position is
Z-phase position.
During multi-point orientation control, the stop position is determined by the total value of this parameter and
the position data for multi-point orientation of PLC input.
---Setting range---
-35999 to 35999 (0.01°)
#3107
ori_spd
Orientation command speed
#3108
ori_sft
Position shift amount for orientation
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......