M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
701
IB-1501279-H
Specify the upper limits of machine-end speed determined as safe for each of SSM speeds 1 to 4. If the com-
mand/FB speed is at the safe speed or lower while SSM is ON, the Under SSM safe speed signal turns ON.
If the command/FB speed exceeds the safe speed, the Under SSM safe speed signal turns OFF. The safe
speed to be applied to SSM is calculated using the following equation.
(When the Under SSM safe speed signal is ON)
Safe speed = SSM speed
(When the Under SSM safe speed signal is OFF)
Safe speed = SSM speed - SSM hysteresis width
---Setting range---
0 to 999999.9 (r/min)
Specify the hysteresis widths that correspond to SSM speeds 1 to 4. For details refer to SSM speeds 1 to 4.
---Setting range---
0 to 999999.9 (r/min)
Specify the upper limit of machine-end speed determined as a safe operating stop.
If the SOS_V detection delay time has elapsed with the command/FB speed exceeding that of this pa-
rameter while SOS is ON, a safe stop (SS1 or STO) is executed.
The point of time at which the command/FB speed drops to that of this parameter or lower while SS1/
SS2 is ON is treated as a standstill.
*When this parameter is set to 0, "SOS speed error" may occur even though the spindle is at a standstill.
---Setting range---
0 to 9999.9 (r/min)
Specify a period of time to detect a speed error while SOS is ON. If the period of time set in this parameter
has elapsed with the command/FB speed exceeding the SOS stop speed while SOS is ON, a safe stop (SS1
or STO) is executed.
---Setting range---
0 to 9999 (ms)
Specify the upper limit of machine-end position deviation determined as a safe operating stop. If the SOS_PD
detection delay time has elapsed with the position deviation (difference between the command and FB posi-
tions) exceeding that of this parameter while SOS is ON, a safe stop (SS1 or STO) is executed.
* When this parameter is set to 0, "SOS position deviation error" may occur even though the spindle is at a
standstill.
---Setting range---
0 to 9999 (°)
Specify a period of time to detect a position deviation error while SOS is ON. If the time set in this parameter
has elapsed with the position deviation (difference between the command and FB positions) exceeding the
SOS position deviation tolerance while SOS is ON, a safe stop (SS1 or STO) is executed.
---Setting range---
0 to 9999 (ms)
Specify the upper limit of machine-end travel distance (minus side) determined as a safe operating stop. If
the SOS_P detection delay time has elapsed with the command/FB travel distance in the minus direction ex-
ceeding that of this parameter while SOS is ON, a safe stop (SS1 or STO) is executed.
*When this parameter is set to 0, "SOS travel distance error" may occur even though the spindle is at a stand-
still.
---Setting range---
0 to 9999 (°)
(PR)
#51326-
51329
SSM_SSpeed1-4
SSM speed 1-4
#51330-
51333
SSM_SHysteresis1-4
SM hysteresis width 1-4
(PR)
#51334
SOS_SSpeed
SOS stop speed
#51335
SOS_ST1
SOS_V detection delay time
(PR)
#51336
SOS_SDroop
SOS position deviation tolerance
#51337
SOS_ST2
SOS_PD detection delay time
(PR)
#51338
SOS_SPositionM
SOS travel distance tolerance (-)
Summary of Contents for C80 Series
Page 1: ......
Page 7: ......
Page 11: ......
Page 13: ......
Page 15: ......
Page 18: ...1 IB 1501279 H Alarm ...
Page 19: ...M800 M80 E80 C80 Series Alarm Parameter Manual 2 IB 1501279 H ...
Page 20: ...1 3 IB 1501279 H Operation Errors M ...
Page 54: ...2 37 IB 1501279 H Stop Codes T ...
Page 62: ...3 45 IB 1501279 H Servo Spindle Alarms S ...
Page 81: ...M800 M80 E80 C80 Series Alarm Parameter Manual 3 Servo Spindle Alarms S 64 IB 1501279 H ...
Page 82: ...4 65 IB 1501279 H MCP Alarms Y ...
Page 98: ...5 81 IB 1501279 H System Alarms Z ...
Page 111: ...M800 M80 E80 C80 Series Alarm Parameter Manual 5 System Alarms Z 94 IB 1501279 H ...
Page 112: ...6 95 IB 1501279 H Absolute Position Detection System Alarms Z7 ...
Page 118: ...7 101 IB 1501279 H Distance coded Reference Scale Errors Z8 ...
Page 120: ...8 103 IB 1501279 H Emergency Stop Alarms EMG ...
Page 124: ...9 107 IB 1501279 H Computer Link Errors L ...
Page 126: ...10 109 IB 1501279 H User PLC Alarms U ...
Page 136: ...11 119 IB 1501279 H Network Service Errors N ...
Page 139: ...M800 M80 E80 C80 Series Alarm Parameter Manual 11 Network Service Errors N 122 IB 1501279 H ...
Page 140: ...12 123 IB 1501279 H Program Errors P ...
Page 178: ...13 161 IB 1501279 H Smart Safety Observation Alarm V ...
Page 192: ...14 175 IB 1501279 H Multi CPU Errors A C80 ...
Page 215: ...M800 M80 E80 C80 Series Alarm Parameter Manual 14 Multi CPU Errors A C80 198 IB 1501279 H ...
Page 216: ...199 IB 1501279 H Parameter ...
Page 217: ...M800 M80 E80 C80 Series Alarm Parameter Manual 200 IB 1501279 H ...
Page 218: ...15 201 IB 1501279 H User Parameters ...
Page 359: ...M800 M80 E80 C80 Series Alarm Parameter Manual 15 User Parameters 342 IB 1501279 H ...
Page 360: ...16 343 IB 1501279 H Machine Parameters ...
Page 748: ......