*1 <Cooling> Indoor temperature: 27°CDB/19°CWB (81°FDB/66°FWB) Outdoor temperature: 35°CDB (95°FDB)
<Heating> Indoor temperature: 20°CDB (68°FWB) Outdoor temperature: 7°CDB/6°CWB (45°FDB/43°FWB)
*2 Figures in the parentheses indicate drainpump-less Model (L).
Model
PEFY-
M50VMA2-A
PEFY-
M63VMA2-A
PEFY-
M71VMA2-A
PEFY-
M80VMA2-A
Power supply
Voltage
V
1-phase 220-230-240
Frequency
Hz
50
Cooling capacity
*1
kW
16.0
Heating capacity
*1
kW
18.0
Power consumption
*2
Cooling
kW
0.208(0.206)
Heating
kW
0.206
Current consumption
Cooling
A
1.40
Heating
A
1.40
External finish
Galvanized
Dimensions
Height
mm
250
Width
mm
1600
Depth
mm
732
Net weight
*2
kg
42(41)
Heat exchanger
Cross fin (Aluminium fin and copper tube)
Fan
Type
Sirocco fan x 3
Airflow rate
(Low-Mid-High)
m
3
/min
29.5-35.5-40.0
External static
pressure
Pa
40/50/70/100/150
Motor
Output
kW
0.300
Air filter
PP Honeycomb fabric (washable)
Refrigerant pipe
dimensions
Gas (Brazed
connection)
mm[in.]
ø12.7[ø1/2]
ø15.88[ø5/8]
Liquid (Brazed
connection)
mm[in.]
ø6.35[ø1/4]
ø9.52[ø3/8]
Drain pipe dimensions
mm[in.]
O.D. 32[1-1/4]
Operating noise(Low-Mid-High)
35Pa / 40Pa
dB (A)
30-34-36
50Pa
30-34-37
70Pa
31-35-37
100Pa
32-36-39
150Pa
34-38-42
35Pa / 40Pa
33-37-39
50Pa
33-37-40
70Pa
34-38-40
100Pa
35-39-42
150Pa
37-41-45
Measurement location 1
Aux. duct
*
Measured in anechoic room.
2m
2m
1.
5m
*
Measured in anechoic room.
2m
1m
Aux. duct
1.
5m
Measurement location 2
HWE19070.book Page 9 Thursday, September 12, 2019 3:46 PM