1. Safety precautions

  Before operating the unit, make sure you read all the “Safety 

precautions”.

  “Safety  precautions”  lists  important  points  about  safety. 

Please be sure to follow them.

Symbols used in the text

 Warning:

Describes precautions that should be observed to avoid the risk of injury or 
death to the user.

 Caution:

Describes precautions that should be observed to prevent damage to the unit.

Symbols used in the illustrations

  :  Indicates an action that must be avoided.

  :  Indicates that important instructions must be followed.

  :  Indicates a part which must be grounded.

  :  Indicates that caution should be taken with rotating parts. (This symbol is 

displayed on the main unit label.) <Color: yellow>

  :  Beware of electric shock. (This symbol is displayed on the main unit label.) 

<Color: yellow>

 Warning:

Carefully read the labels affixed to the main unit.

1.1.  Installation

 

After you have read this manual, keep it and the Installation Manual in a 
safe place for easy reference whenever a question arises. If the unit is 
going to be operated by another person, make sure that this manual is 
given to him or her.

 Warning:

•  The unit should not be installed by the user. Ask the dealer or an author-

ized company to install the unit. If the unit is installed improperly, water 
leakage, electric shock or fire may result.

•  Use only accessories authorized by Mitsubishi Electric and ask your dealer 

or  an  authorized  company  to  install  them.  If  accessories  are  installed 
improperly, water leakage, electric shock or fire may result.

•  The Installation Manual details the suggested installation method. Any 

structural  alteration  necessary  for  installation  must  comply  with  local 
building code requirements.

•  Never repair the unit or transfer it to another site by yourself. If repair is 

performed improperly, water leakage, electric shock or fire may result. If 
you need to have the unit repaired or moved, consult your dealer.

•  Keep the electric parts away from water (washing water) etc.
•  It might result in electric shock, catching fire or smoke.

Note1: When washing the Heat Exchanger and Drain Pan, ensure the Con-

trol Box, Motor and LEV remain dry, using a water proof covering.

Note2: Never  drain  the  washing  water  for  the  Drain  Pan  and  the  Heat 

Exchanger using the Drain Pump. Drain separately.

•  The appliance is not intended for use by young children or infirm persons 

without supervision.

•  Young children should be supervised to ensure that they do not play with 

the appliance.

•  Do not use a leak detection additive.
•  Do not use refrigerant other than the type indicated in the manuals pro-

vided with the unit and on the nameplate.

Doing so may cause the unit or pipes to burst, or result in explosion or fire during 
use, during repair, or at the time of disposal of the unit.

It may also be in violation of applicable laws.

MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for mal

-

functions or accidents resulting from the use of the wrong type of refrigerant.

1)  Outdoor unit

 Warning:

•  The outdoor unit must be installed on a stable, level surface, in a place 

where there is no accumulation of snow, leaves or rubbish.

•  Do not stand on, or place any items on the unit. You may fall down or the 

item may fall, causing injury.

 Caution:

The outdoor unit should be installed in a location where air and noise emitted 
by the unit will not disturb the neighbours.

2)  Indoor unit

 Warning:

The indoor unit should be securely installed. If the unit is loosely mounted, 
it may fall, causing injury.

3)  Remote controller

 Warning:

The remote controller should be installed in such a way that children cannot 
play with it.

4)  Drain hose

 Caution:

Make sure that the drain hose is installed so that drainage can go ahead 
smoothly. Incorrect installation may result in water leakage, causing dam-
age to furniture.

5)  Power line, fuse or circuit breaker

 Warning:

•  Make sure that the unit is powered by a dedicated supply. Other appliances 

connected to the same supply could cause an overload.

•  Make sure that there is a main power switch.
•  Be sure to adhere to the unit’s voltage and fuse or circuit breaker rat-

ings. Never use a piece of wire or a fuse with a higher rating than the one 
specified.

6)  Grounding

 Caution:

•  The unit must be properly grounded. Never connect the grounding wire 

to a gas pipe, water pipe, lightning conductor or tele phone grounding 
wire. If the unit is not grounded properly, electric shock may result.

•  Check frequently that the ground wire from the outdoor unit is properly con-

nected to both the unit’s ground terminal and the grounding electrode. 

1.2.  During operation

 Caution:

•  Do not use any sharp object to push the buttons, as this may damage the 

remote controller.

•  Do not twist or tug on the remote controller cord as this may damage the 

remote controller and cause malfunction.

•  Never remove the upper case of the remote controller. It is dangerous 

to remove the upper case of the remote controller and touch the printed 
circuit boards inside. Doing so can result in fire and failure.

•  Never wipe the remote controller with benzene, thinner, chemical rags, 

etc. Doing so can result in discoloration and failure. To remove heavy 
stains, soak a cloth in neutral detergent mixed with water, wring it out 
thoroughly, wipe the stains off, and wipe again with a dry cloth.

•  Never block or cover the indoor or outdoor unit’s intakes or outlets. Tall 

items of furniture underneath the indoor unit, or bulky items such as large 
boxes placed close to the outdoor unit will reduce the unit’s efficiency.

Contents

1.  Safety precautions ........................................................................................

5

 

1.1.  Installation ...................................................................................

5

 

1.2.  During operation .........................................................................

5

 

1.3.  Disposing of the unit ...................................................................

6

2.  Names and functions of various parts ..........................................................

6

3.  How to operate .............................................................................................

6

 

3.1.  ON/OFF ......................................................................................

6

 

3.2.  Selecting operation .....................................................................

6

 

3.3.  Room temperature adjustment ...................................................

7

 

3.4.  Fan speed adjustment.................................................................

7

 

3.5.  Ventilation ...................................................................................

7

 

3.6.  Others .........................................................................................

7

4.  The smart way to use ...................................................................................

7

5.  Caring for the machine .................................................................................

8

6.  Troubleshooting ............................................................................................

8

7.  Installation, transferring works, and checking ...............................................

9

8.  Specifications ...............................................................................................

9

Note:

 If you use other remote controllers, refer to either Installation Manual or Initial Setting Manual that comes with the controller to be used.

Summary of Contents for CITY MULTI PEFY-P06NMAU-E3

Page 1: ...MANUAL For safe and correct use please read this installation manual thoroughly before installing the air conditioner unit MANUEL D INSTALLATION Veuillez lire le manuel d installation en entier avant d installer ce climatiseur pour éviter tout accident et vous assurer d une utilisation correcte ...

Page 2: ... 1 8 400 500 15 3 4 19 11 16 1500 59 1 16 2000 78 3 4 PEFY P54NMAU E3 1600 63 500 600 19 11 16 23 5 8 1700 66 15 16 2200 86 5 8 Unit mm in G H I F 700 27 9 16 450 17 3 4 475 18 3 4 450 17 3 4 Q 50 150 2 5 15 16 450 17 3 4 450 17 3 4 100 200 3 15 16 7 7 8 Min 300 11 13 16 P E A D H G Min 20 13 16 Min 10 7 16 B C A B J P 50 2 R 777 30 5 8 450 17 3 4 475 18 3 4 700 27 9 16 50 2 Min 300 11 13 16 E A I...

Page 3: ...draining A Unit body B Lifting machine C Nuts field supply D Washers square accessory E M10 hanging bolt field supply 5 5 2 Fig 5 1 1 Fig 5 1 2 5 1 6 6 2 Fig 6 2 1 A Center of gravity A Indoor unit s bottom surface A Y X L W A Z C D C E D B A 137 5 7 16 67 2 5 8 239 9 7 16 357 14 1 16 122 4 13 16 33 1 5 16 41 1 5 8 217 8 9 16 C A B D Fig 5 2 1 Unit mm in ...

Page 4: ...as large as possible About 10 cm 3 15 16 in F Indoor unit G Make the piping size large for grouped piping H Downward slope 1 100 or more I O D ø38 mm 1 1 2 in PVC TUBE for grouped piping 9 mm 3 8 in or more insulation J Up to 700 mm 27 9 16 in N Drain hose accessory O Horizontal or slightly upgradient 7 2 Fig 7 2 2 C B A L D D D E K M B H I Max 20 m 65 ft 1 5 2 m 5 7 ft G F F F B C D D G F E H A 3...

Page 5: ... to 1 5 8 in B Remove the water supply port C About 2500 cc D Water E Filling port F Screw Fig 8 0 2 SWE Fig 7 3 2 Fig 8 0 3 Fig 8 0 4 Indoor controller board A B F C D E A B G F A C E D A B G C E A F D A B A Filter B Bottom plate C Nail for the bottom inlet D Nail for the rear inlet C D A In case of rear inlet B In case of bottom inlet A Duct B Air inlet C Access door D Canvas duct E Ceiling surf...

Page 6: ...together to the S terminal Dead end connection E Insulation tape To keep the earth wire of the shielded cable from coming in contact with the transmis sion terminal 9 3 Fig 9 3 3 Fig 9 3 4 Fig 9 3 5 C Terminal box D Knockout hole E Remove A Screw holding cover 1pc B Cover Fig 9 3 1 Fig 9 3 2 A Non polarized B TB15 C Remote Controller D TB5 Fig 9 2 3 Fig 9 2 4 2 S M2 M1 A B D 1 DC10 13V A B 1 2 L1 ...

Page 7: ...tall the accessories Improper installation by the user may result in water leakage electric shock or fire Never repair the unit If the air conditioner must be repaired consult the dealer If the unit is repaired improperly water leakage electric shock or fire may result If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to...

Page 8: ...e its parts When installing the unit in a hospital communication station or similar place provide sufficient protection against noise The inverter equipment private power generator high frequency medical equipment or radio communication equipment may cause the air conditioner to operate erroneously or fail to operate On the other hand the air conditioner may affect such equipment by creating noise...

Page 9: ...e W mm in L mm in X mm in Y mm in Z mm in Product Weight kg lb PEFY P06NMAU E3 643 25 5 16 754 29 11 16 330 13 300 11 13 16 130 5 1 8 22 49 PEFY P08NMAU E3 643 25 5 16 754 29 11 16 330 13 300 11 13 16 130 5 1 8 22 49 PEFY P12NMAU E3 643 25 5 16 754 29 11 16 330 13 300 11 13 16 130 5 1 8 22 49 PEFY P15NMAU E3 643 25 5 16 954 37 9 16 340 13 3 8 375 14 3 4 130 5 1 8 26 58 PEFY P18NMAU E3 643 25 5 16 ...

Page 10: ...or accidents resulting from the use of the wrong type of refrigerant Caution Use refrigerant piping made of C1220 Cu DHP phosphorus deoxidized copper as specified in the JIS H3300 Copper and copper alloy seamless pipes and tubes In addition be sure that the inner and outer surfaces of the pipes are clean and free of hazardous sulphur oxides dust dirt shaving particles oils moisture or any other co...

Page 11: ...ulation to inlet duct flange and outlet duct to prevent condensa tion Be sure to change the position of air filter to the position where it can be serv iced Fig 8 0 1 P 5 A In case of rear inlet B In case of bottom inlet A Duct B Air inlet C Access door D Canvas duct E Ceiling surface F Air outlet G Leave distance enough to prevent short cycle Procedure for changing the rear inlet to the bottom in...

Page 12: ...length 200 m Maximum length of transmission lines for centralized control and indoor outdoor transmission lines Maximum length via indoor units 500 m MAX The maximum length of the wiring between power supply unit for transmission lines on the transmission lines for centralized control and each outdoor unit and system controller is 200 m When 10 m is exceeded use cables with the same specification ...

Page 13: ...ved it cannot operate normally 9 4 External I O specifications Caution 1 Wiring should be covered by insulation tube with supplementary insula tion 2 Use relays or switches with IEC or equivalent standard 3 The electric strength between accessible parts and control circuit should have 2750 V or more 9 2 Connecting remote controller indoor and outdoor transmission cables Connect indoor unit TB5 and...

Page 14: ... varies with the system at site Set them referring to the Data Book 9 7 Sensing room temperature with the built in sensor in a remote controller If you want to sense room temperature with the built in sensor in a remote control ler set SW1 1 on the control board to ON The setting of SW1 7 and SW1 8 as necessary also makes it possible to adjust the air flow at a time when the heating thermometer is...

Page 15: ...ress telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...

Page 16: ... F OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur ...

Page 17: ...F FILTER CHECK CLEAR MENU ON OFF TEST TEMP CLOCK OPERATION BACK DAY MONITOR SET 1 2 3 4 D 5 6 8 9 C 0 A B 7 Remote controller Button Touche Commande à distance GB F 1 Touche Réglage de la température 2 Touche Timer Menu 3 Touche Mode Touche Monitor Set Touche Back 4 Touche Timer On Off 5 Touche Louvre Touche Set Day Touche Operation 6 Touche Vitesse du ventilateur 7 Touche Commande des ailettes 8 ...

Page 18: ...pièce N Réglage des ailettes O Vitesse du ventilateur P Témoin de fonctionnement Remote controller Display Affichage Commande à distance GB F A Current time Timer time B Centralized control indicator C Timer OFF indicator D Timer mode indicator E Operation mode display COOL DRY AUTO FAN HEAT F Function mode indicator G Preset temperature H Power indicator I Louver J Ventilation K Filter sign L Sen...

Page 19: ...4 4 2 In case of bottom inlet En cas d entrée sur le dessous 1 In case of rear inlet En cas d entrée arrière A Filter Filtre Air Flow Flux d air A 1 A 2 Fig A ...

Page 20: ...use of the wrong type of refrigerant 1 Outdoor unit Warning The outdoor unit must be installed on a stable level surface in a place where there is no accumulation of snow leaves or rubbish Do not stand on or place any items on the unit You may fall down or the item may fall causing injury Caution The outdoor unit should be installed in a location where air and noise emitted by the unit will not di...

Page 21: ...it consult your dealer If pipes are removed incorrectly refrigerant fluorocarbon gas may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environment 2 Names and functions of various parts Attachment and detachment of filter Fig A P 4 3 How to operate Before starting operation Start running after the PLEASE WAIT display has dis...

Page 22: ...on according to the change of the room temperature and automatically repeat ON OFF 2 When reaching room temperature of your choice Both the compressor and indoor fan stop When stop continues for 10 minutes the compressor and indoor fan are oper ated for 3 minutes to keep the humidity low For heating Press the 3 Mode BACK Button to bring up the HEAT display Regarding displays during heating operati...

Page 23: ... Heating operation starts after ending defrosting operation It runs briefly but soon stops The CHECK and check code flashes on the liquid crystal display There are some obstacles at the air inlet and outlet of the indoor and outdoor units Rerun after removal The filter is filled with dust and dirt Rerun after cleaning the filter Refer to Caring for the machine The sound of the exhaust and rotation...

Page 24: ...f the professional engineering work required for transferring the instal lation Caution When moving or reinstalling the air conditioner consult with your dealer Defective installation can result in electric shock fire etc Regarding noise In installing work choose a place that can fully bear the weight of the air con ditioner and where noise and vibration can be reduced Choose a place where cool or...

Page 25: ...The operating noise is the data that was obtained in an anechoic room Item Model P36NMAU E3 P48NMAU E3 P54NMAU E3 Power source 208 230V 60Hz Cooling capacity 1 Heating capacity 1 Btu h 36 000 40 000 48 000 54 000 54 000 60 000 kW 10 6 11 7 14 1 15 8 15 8 17 6 Dimension Height mm in 250 9 13 16 Width mm in 1 400 55 1 8 1 600 63 Depth mm in 732 28 7 8 Net weight kg lb 39 86 42 93 Fan Airflow rate Lo...

Page 26: ...ress telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...

Reviews: