12
PEFY-P200·250VMH-E
connector to alter the external static pressure on the fan
BREAKER
*NOTE 1
*NOTE 1,2
*A
connector is attached to the drain lift up mechanism, which is an optional part.
*
NOTE 1
Switch(for model selection) Switch(for voltage selection)
Switch(for mode selection)
Switch (connection No.set)
Switch (2nd digit address set)
Switch(for capacity code)
Switch(for mode selection)
Thermistor (piping temp.detection/gas)
Thermistor (piping temp.detection/liquid)
Aux.relay
POWER SUPPL
Y
3N~ 380/400/415V 50/60Hz
TO DUCT
TO OUTDOOR UNIT BC CONTROLLER REMOTE CONTROLLER
CAUTION;1.T
o protect Fan motor from abnormal current, Over current relays<51F>
is installed.
Therefore, do not change factory set value of Over
current relays.
52F
Contactor (fan motor)
Over current relay (fan motor)
49F
Inner thermostat
51F
<F2>
inside < > is the optional parts.
NAME
SYMBOL
EXPLANA
TION
Power source terminal bed T
ransmission terminal bed
TB5
Transmission terminal bed
TB15
TB2
T
ransformer
Address board
Indoor controller board
Electronic linear expan. valve
Fan motor
LEV1,LEV2
T
A.B
I.B
MF
SYMBOL
<DS>
<DP>
F1
Fuse
AC250V 6.3A
F
Fuse
AC250V 5A
F
S.B
Surge absorber board
Drain sensor
Drain Pump
SW4(I.B) SW5(A.B)
SW1(A.B)
SW14(A.B)
SW12(A.B)
SW1
1(A.B)
SW3(I.B)
SW2(I.B)
Switch (1st digit address set)
SYMBOL
NAME
TH22
TH23
Thermistor (inlet temp.detection)
TH21
X04
~
X06
NOTE;1.The part of the broken line indicates the circuit for optional parts.
2. *A
in the chart is the connector for a drain pump test run operation.
(The Drain Pump operates continuously if the connector is inserted and the power is supplied.)
After the test run, make sure to remove the *A
connector
.
3.The wirings to
TB2,TB5 shown in dotted line are field work.
4.Mark indicates terminal bed, connector
, board insertion
connector or fastening connector of control board.
( 5A
)
Colour/External Static Pressure Blue/1
10Pa(at 380V),130Pa(at 400,415V)
White/220Pa(at 380V),260Pa(at 400,415V)
TB2
TB5(TRANSMISSION TERMINAL
BED)
TO MA REMOTE CONTROLLER
TB15(TRANSMISSION TERMINAL
BED)
8 7
5
6
4
3
2
0
9
1
F E
D C B A
9
9
0
1 2 3 4
5
6
7
8
0
87
65
4
3
21
51F
Drain sensor
56
52F
PE
N
L3
L2
PE
CR
SW5
2 1
I.B
CN2M
FAN3
CNP
CND
CNT
CN60
CN31
CN21
CN20
CN81
1 2 3 4 5 6
11
1
1
1
31
5
8
2
22
3
3
1
3
3
CN31
4
6
1
5
2
6
L1
DP
MF
DS
TH22
SW3
SW2
1
3
CN3T
A.B
6 5 4 3 2 1
7
8
CN29
1
2
TH23
8
7
1
234
1 2 3 4
CN42
SW4
31
TH21
7
9
5
9
4
(Blue)
CN62
CN82
ZNR
8
2
3
49F
1
1
2
34
5
6
89
52F
*A
T
1
2
3
4
5
6
LEV1
1
2
3
4
5
6
6
54
32
1
65
43
21
LEV2
6
54
321
F1
F2
SW12 (2nd digit)
SW1
1
(1st digit)
SW14
(Connection No.)
ZNR1
3
1
CN1
DSA1
S.B
(White)
SW1
M2 M1
3 1
CN3A
2 1
1
2
2
1
1
2
INSIDE SECTION OF CONTROL
BOX
LEV adapter board
S(SHIELD)
X01
X05
X06
X04
AC250V 6.3A
F
AC250V 5A
F