background image

Mitsubishi Electric Sales Canada Inc.

www.MitsubishiElectric.ca

 

Specifications are subject to change without notice.

Model:

 PKFY

-P15NHMU-E2 – DIMENSI

ONS

SB_PFY-P15NHMU-E2_201205

Mitsubishi Electric Air Conditioning & Refrigeration Systems Wo rks acquired ISO 

based on a review of quality warranties for the production of refrigeration and air 

conditioning equipment.

ISO Authorization System

The ISO 9000 series is a plant authorization system relating to quality warranties as 

development, production, installation and auxiliary services" for products built at 

an authorized plant.

Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmental

The ISO 14000 series is a set of standards applying to environmental protection set by the 

International Standard Organization (ISO). 

Unit : in(mm)

1/2F (    12.7)

1/4F (    6.35)

Refrigerart

Piping

Drain hose

Gas pipe

Liquid pipe

   2-1/2

~

   3-1/8

 (   65

~     

80)

   2-1/2

~     

3-1/8

 (   65

~     

80)

Through hole

Sleeve

(purchased locally)

Center measurement hole   3/32(  2.5) 

5/32(3.8)

2-1/4(58)

0

Wall hole

 for

left rear

 piping

Knock out hole for

left rear piping

2-3/4×12-3/16(70×310)

Wall hole for

right rear piping

77-   3/16(   5.1)

Tapping

screw hole

4-   5/16(   9) Bolt hole

Mount board

Indoor unit outline

0

5/8(16)

9-15/16(253.5)

9-1/8(232.5)

1-1/16(28.5)

1-9/16(41)

3-1/16(78.5)

4-1/16(103.5)

4-9/16(116)

6-1/2(166)

7(178.5)

8(203.5)

3-9/16(91)

13/16(21.8)

9-1/16(231.5)
10-3/4(273.2)

0

1-1/4(32.7)
2-9/16(66)

2-1/16(53.5)

5(128.5)

6(153.5)

3/4(20)

9/16(15)

14-5/8(372.3)

14(356.3)

12-7/8(237.5)

11-7/16(291.5)

10-3/8(265)

9-5/16(238)

8-13/16(225)

7-13/16(200)

4-7/8(125)

2-3/4(70)

9/16(15)

14-5/8(372.3) 14(356.3) 12-7/8(327.5)

10-3/8(265)

11-7/16(291.5)

7-13/16(200)

8-13/16(225)

4-7/8(125)

2-3/4(70)

0

17-5/8(449)

7-9/16(193.5)

7-1/16(180.3)

6-9/16(167)

5-1/2(140)

4-1/2(1

15)

6-13/16(174)

8-3/8(213)

9-5/16(238)

10-15/16(278.3)

15-1/2(394)

11-1/16(281)

17-5/8(449)

0

Emergency operation switch

(cooling/heating)

Terminal block for 

MA-remote controller

Terminal block for transmission

Front side(Grille open)

Terminal block for power supply

17-15/16(457)Gas pipe

21-3/16(539)Liquid pipe

6-5/8(169)
6-3/16(158)

24(610)Drain hose

7-3/16(184)

250mm,9-13/16inch or greater with

 

optional drain pump installation.

Required space(Indoor unit)

(mm)

Air inlet

Air inlet

Air outlet

Min.1-31/32(50)

Min.9-13/16(250)

Min.5-7/8(150)

Min.8-5/8

(220)

Min.1-31/32(50)

Min.1/4(7)

Knock out hole for piping

D

2-3/16(56)

2-1

1/16(69)

3/16(6)

1-11/16(43)

C

2-3/16(56)

7/16(12.5)

1-1

1/16(43)

B

1-3/4(46)

2-5/16(60)

2-5/16(59)

1-1

1/16(43)

A

1-11/16(43)

1-3/4(46)

2-3/16(56)

3/16(6)

A

Knock out hole

for right piping

Right side

Mount board

3/16(5)

9-3/4(249)

Top side

15-3/16(387)

7-1/2(192)

7-3/4(197)

23-9/16(599)

C

B

Operation lamp

DEFROST/STAND BY lamp

Receiver

Louver(manual)

Vane(auto)

Knock out hole

for lower piping

Knock out hole

for lower piping

Under side

5/16(8)

24-1/16(612)

D

Knock out hole

for left piping

Left side

Front side

6-1/16(155)

2-1/8

(55)

27-1/16(688)

11-9/16(295)

35-5/16(898)

5/8 (    16) I.D

Reviews: