19
MODELS
P20VBM
SW2
123456
ON
OFF
P25VBM
123456
ON
OFF
P32VBM
123456
ON
OFF
P40VBM
123456
ON
OFF
SW3
1234567
ON
OFF
1234567
ON
OFF
123456
ON
OFF
123456
7
7
8
8
8
8
9
9
9
9
10
10
10
10
ON
OFF
<
1>
[LEGEND]
SYMBOL
NAME
I.B
INDOOR CONTROLLER BOARD
CN25
CN27
CN32
CN51
CN52
SW2
SW3
SW4
SWE
CONNECTOR HUMIDIFIER
DAMPER
REMOTE SWITCH
A.B
CIRCUIT BOARD
SW1
SW5
SW11
SW12
MODE SELECTION
VOLTAGE SELECTION
ADDRESS SETTING 1s DIGIT
ADDRESS SETTING 10ths DIGIT
SW14
BRANCH No.
CENTRALLY CONTROL
REMOTE INDICATION
SWITCH
SWITCH
CAPACITY CORD
MODE SELECTION
MODEL SELECTOR
ZNR
VARISTOR
DRAIN UP MACHINE
(
TEST MODE
)
X1
AUX.RELAY
FUSE FUSE
(
T6.3AL 250V
)
LED1 POWER SUPPLY
(
I.B
)
LED2 POWER SUPPLY
(
I.B
)
SYMBOL
NAME
TH21
DS
MF
MV
DP
THERMISTOR ROOM TEMP. DETECTION
(
0°C/15k
Ω
, 25°C/5.4k
Ω
)
PIPE TEMP. DETECTION / LIQUID
(
0°C/15k
Ω
, 25°C/5.4k
Ω
)
PIPE TEMP. DETECTION / GAS
(
0°C/15k
Ω
, 25°C/5.4k
Ω
)
LEV
LINEAR EXPANSION VALVE
TH22
TH23
DRAIN SENSOR
FAN MOTOR
VANE MOTOR
DRAIN PUMP
DRAIN PUMP
TB2
TB5
TB15
TRANSMISSION
MA-REMOTE CONTROLLER
TERMINAL
BLOCK
POWER SUPPLY
NOTES:
1.At servicing for outdoor unit,always follow the wiring diagram of outdoor unit.
2.In case of using MA-Remote controller, please connect to TB15.
(Remote controller wire is non-polar.)
3.In case of using M-NET, please connect to TB5. (Transmission line is non-polar.)
4.Symbol
[
S
]
of TB5 is the shield wire connection.
5.Symbols used in wiring diagram above are,
: terminal block, :connecter.
6.The setting of the SW2 dip switches differs in the capacity. For the detail, refer to the table below.
7.Please set the switch SW5 according to the power supply voltage.
Set SW5 to 240V side when the power supply is 230 and 240 volts.
When the power supply is 220 volts, set SW5 to 220V side.
Mark
Meaning
Function
Power supply for
MA-Remote controller
Main power supply (Indoor unit:220-240V)
Power on
→
Iamp is lit
LED on indoor board for service
LED1
Main power supply
Power supply for MA-Remote controller
on
→
Iamp is lit
LED2
SWE
ON OFF
CN2M
(
BLU
)
M-NET
CN3A
(
BLU
)
REMOCON
TB5
(SHIELD)
M1 M2
TB2
TB15
1
S
TH23
TH22
CN20
(
RED
)
INTAKE
CN60
(
WHT
)
LEV
CN52
(
GRN
)
REMOTE
INDICATION
CN6V1
(
GRN
)
VANE
TH21
CNMF2
(
WHT
)
CNMF1
(
WHT
)
CN31
(
WHT
)
DRAIN
CN44
(
WHT
)
LIQUID
/GAS
CN25
(
WHT
)
CN27
(
RED
)
ADDRESS
CN81
(
RED
)
CN42
(
RED
)
ADDRESS
CN32
(
WHT
)
REMOTE SWITCH
X1
CNP
(
YLW
)
D.U.M
CND
(
BLK
)
FUSE
DSA
ZNR01
DC311
~
339V
ZNR02
U
CN51
(
WHT
)
CENTRALLY
CONTROL
CN41
(
WHT
)
HA
4
8
5
5
LEV
M
DS
DP
t°
t°
t°
t°
2
L
N
1 2 3 4 5 6 7 8 910
SW3
1 2 3 4 5 6
SW2
1 2 3 4 5
SW4
8
1
5
1
5
1
3
6
1
6
1
5
1
4
1
2
1
2
1
2
1
4
1
1
3
3
1
3
1
3
1
2
1
2 1
1
4
1
3
5
7
8 6 4 2
I.B
M
1~
M
U
MS
3~
PULL BOX
FUSE
(
15A
)
BREAKER
(
15A
)
POWER SUPPLY
~
/ N
220-240V 50Hz
220V 60Hz
TO NEXT
INDOOR
UNIT
BLU
BRN
ORN
YLW
RED
WHT
SW14
SWC
BRANCH
No.
SW11
1s
DIGIT
SW12
10ths
DIGIT
1 2 3 4 5 6 7 8 910
SW1
SW5
240V
220V
(RED)
ADDRESS
CN82
(RED)
ADDRESS
CN43
A.B
8
1
4
1
0 12
3
4
5
67
89
AB
C
D
EF
0 1
2
3
4
5
6
7
8
9
0 1
2
3
4
5
6
7
8
9
TO MA-REMOTE
CONTROLLER
DC8.7-13V
TO OUTDOOR UNIT
BC CONTROLLER
REMOTE CONTROLLER
DC24-30V
RED
BLU
GRN
/YLW
MF
MV
ORN
*See fig :
1
ORN
BLU
BLU
BLU
BLU
LED2
LED1
GRN
YLW
ORN
RED
BRN
BLK
The black square (
■
)
indicates a switch position.
PMFY-P20VBM-E#2 PMFY-P25VBM-E#2
PMFY-P32VBM-E#2 PMFY-P40VBM-E#2
PMFY-P20VBM-ER3 PMFY-P25VBM-ER3 PMFY-P32VBM-ER3 PMFY-P40VBM-ER3
OC307E