![background image](http://html.mh-extra.com/html/mitsubishi-electric/city-multi-r2-series/city-multi-r2-series_manual_22383015.webp)
A height difference of up to 90m from the
outdoor unit to the indoor unit can be
supported with no extra-cost options.
This increases design flexibility and facilitates
installation of these units even in high-rise
buildings.
Height difference from outdoor unit to
indoor unit:
The system can be configured with a
height difference of up to
90m with
no extra-cost options.
* Whether the system can be configured with such a
height difference varies depending on the model.
* The maximum height difference is 60 m when the
outdoor unit is located lower than the indoor unit.
* Requires switch settings.
Usable in an application with a large vertical separation
of up to 90 meters
R2-Series
EP
R2-Series
P
Y-Series
EP
Y-Series
P
Four-way suction and new fan
R2-Series
EP
R2-Series
P
Y-Series
EP
Y-Series
P
Previous model (YLM)
The concave-shaped blade of the propeller fan enables air to flow along the outer circumference of the blade while reducing a
disturbance of air flow that occurs in the upstream and downstream of conventional propeller fans. This helps reduce power
consumption as well as minimises sound levels.
Furthermore, the change of the orientation of the fan blade from the outer circumference direction to the inner circumference
direction reduces air leakage from the outer circumference and sends more air to the upstream of the fan.
Visualization of air flow of fan
Large
Small
Previous three-sided coil design caused fan airflow
turbulence.
Visualization of air flow of fan
New four-sided coil design allows heat exchange without
causing a disturbance of air flow in all directions.
Fan and four-way
suction reduce
disturbance of air flow
Disturbance
• Air suction structure
• Fan structure
Latest model (YNW)
Previous model
(YLM)
Latest model
(YNW)
Air flow
Blade
Inner
circumference
Outer
circumference
Air flow
Large disturbance
Small disturbance
Large disturbance
Small disturbance
Key Components of YNW-Series
15
VRF
Y-Series
VRF
Lineup
VRF
R2-Series
VRF
Zubadan
VRF
WY-Series
VRF
WR2-Series
VRF
S-Series
VRF
Indoor Units
Ventilation
Systems
Technologies and Functions
Remote Controller
Hot Water Solution
VRF
BC Controllers
YNW-Series (Y/R2)
Summary of Contents for City Multi R2 Series
Page 1: ...CM20AN E NZ VRF City Multi Product Catalogue ...
Page 101: ...BC Controllers 101 ...
Page 112: ...Indoor Units VRF 112 ...
Page 114: ...Ceiling Cassette Type 4 Way Airflow Type 114 ...
Page 122: ...Ceiling Cassette Type 2 Way Airflow Type 122 ...
Page 128: ...Ceiling Concealed Type 128 ...
Page 150: ...Wall Mounted Type 150 ...
Page 154: ...Floor Standing Type 154 ...
Page 181: ...Ventilation Systems 181 ...
Page 190: ...Remote Controllers 190 ...