Air distribution
An automatic Air-speed mode automatically adjusts airflow speed to maintain comfortable room conditions at all times.
This setting automatically adjusts the air speed to conditions that match the room environment.
Swing
The air outlet vane swings up and down so that the airflow is spread evenly
throughout the room.
Fan speed setting
A maximum of four fan speeds are available (Low-Middle 2-Middle 1-High). In addition to the four fan speeds, the Auto
mode is available on some models. Various combinations of fan speed and vane angle setting are available to create the
optimum airflow for any given space.
Vane setting
Vertical airflow setting is selectable from a maximum of seven settings (a maximum of five fixed angles, swing, and Auto).
Using different combinations of vertical airflow setting and fan speed, airflow direction and distance can be fine-tuned to
deliver optimum airflow to all corners of the room.
When set to Auto, the vane is directed horizontally in the Cooling, Dry, and Fan modes, and directed downward in the
Heating mode. The available vane angle positions will depend on the remote controller to be used. Refer to the
instruction manual of the relevant remote controller for details.
Strong
Gentle
• While “Standby” or “Defrost” is displayed
• When the room temperature is higher than the set temperature during the heating mode
*The actual air direction will differ from the air direction displayed on the LCD when one of the following conditions is met.
• While “Standby” or “Defrost” is displayed
• When the room temperature is higher than the set temperature during the heating mode
• Immediately after heating operation (during standby for switching the operation mode)
*1 On PAR-FL32MA
Up and down
Fan speed
Remote controller display
Auto
Low
4 levels
3 levels
2 levels
(Middle)
/
The unit operates at high speed at startup to rapidly
heat or cool the space, then automatically slows
down once the target temperature has been reached.
It is more economical than starting up the unit at low
speed and keeping it operating at low speed.
Air speed is automatically reduced when the
target temperature has been reached, saving on
energy costs. There is no more need to
remember to turn down the setting.
At the start of the
heating/cooling operation,
airflow is set to high speed
to quickly heat/cool the
room.
When the room temperature
reaches the desired setting, the
airflow speed is automatically
decreased for stable and
comfortable heating/cooling
operation.
Middle 2
Middle 1
High
Auto
*1
/
Auto
*1
/
Auto
*1
Automatic air-speed adjustment
• Immediately after heating operation (during standby for switching the operation mode)
• During the Dry mode
*The actual fan speed will differ from the fan speed displayed on the LCD when one of the following conditions is met.
PLFY
FM
PEFY
MHS
PEFY
MA
PEFY
MS
PEFY
MX
PFFY
LRM
PKFY
LM
PCFY
KM
PLFY
EM
*1
*1. VLRMM only
PFFY
CM
PKFY
KM
PFFY
CM
PFFY
LRM
PFFY
LEM
PFFY
KM
PKFY
LM
PCFY
KM
PMFY
BM
PLFY
LMD
PLFY
FM
PEFY
MH-F
PEFY
MHS-F
PEFY
MHS
PEFY
MA
PEFY
MS
PEFY
MX
PEFY
MR
PLFY
EM
PKFY
KM
PFFY
KM
PKFY
LM
PCFY
KM
PMFY
BM
PLFY
LMD
PLFY
FM
PLFY
EM
PKFY
KM
PFFY
KM
PKFY
LM
PCFY
KM
PMFY
BM
PLFY
LMD
PLFY
FM
PLFY
EM
178
INDOOR UNIT FUNCTIONS
Summary of Contents for City Multi R2 Series
Page 1: ...CM20AN E NZ VRF City Multi Product Catalogue ...
Page 101: ...BC Controllers 101 ...
Page 112: ...Indoor Units VRF 112 ...
Page 114: ...Ceiling Cassette Type 4 Way Airflow Type 114 ...
Page 122: ...Ceiling Cassette Type 2 Way Airflow Type 122 ...
Page 128: ...Ceiling Concealed Type 128 ...
Page 150: ...Wall Mounted Type 150 ...
Page 154: ...Floor Standing Type 154 ...
Page 181: ...Ventilation Systems 181 ...
Page 190: ...Remote Controllers 190 ...