Dry operation
Convenience
The Dry mode is a dehumidifying mode in which the unit intermittently operates in a mild cooling mode.
During seasons when operating the unit in the Cooling mode tends to overcool the room, such as during the rainy
season, the Dry mode helps keep the room at a comfortable temperature by reducing the room temperature by a few
degrees centigrade.
*The unit cannot be operated in the Dry mode when the room temperature is below 18°C.
*The fan operates at low speed in the Dry mode. (When the user tries to change the fan speed, the fan speed display on the remote controller will change, but the selection will not
actually be reflected.)
Dual set point
Normally, the desired room temperature is set to the same value for cooling and heating. However, the dual set point
function allows different temperatures to be set for cooling and heating. When operation switches from cooling to heating
or vice versa, the preset temperature changes accordingly.
External static pressure setting
PEFY
MH-F
PEFY
MHS-F
PEFY
MHS
PEFY
MA
PEFY
MS
PEFY
MX
PEFY
MR
PFFY
CM
*1
*1. VLRMM only
PFFY
LRM
PKFY
KM
PFFY
CM
PFFY
LRM
PFFY
LEM
PFFY
KM
PKFY
LM
PCFY
KM
PMFY
BM
PLFY
LMD
PLFY
FM
PEFY
MHS
PEFY
MA
PEFY
MS
PEFY
MX
PEFY
MR
PLFY
EM
PKFY
KM
PFFY
CM
PFFY
LRM
PFFY
LEM
PFFY
KM
PKFY
LM
PCFY
KM
PMFY
BM
PLFY
LMD
PLFY
FM
PEFY
MHS
PEFY
MA
PEFY
MS
PEFY
MX
PEFY
MR
PLFY
EM
High efficiency filter
The high efficiency filter has a much finer mesh compared to standard filters, and is capable of capturing minute
particulates floating in the air that were not previously caught.
External static pressure settings are selectable in fine steps according to the inlet/outlet directions and duct length.
*External static pressure setting is set with the DipSW on the indoor unit. Contact your local distributor for details.
Automatic restoration after power failure
Power failure
Power restoration
The unit
automatically
restarts.
No need for manual restart
PKFY
KM
PFFY
CM
PFFY
LRM
PFFY
LEM
PFFY
KM
PKFY
LM
PCFY
KM
PMFY
BM
PLFY
LMD
PLFY
FM
PEFY
MH-F
PEFY
MHS-F
PEFY
MHS
PEFY
MA
PEFY
MS
PEFY
MX
PEFY
MR
PLFY
EM
PCFY
KM
PLFY
EM
Optional
Optional
Upon restoration of power, the unit will automatically resume operation in the mode it was in before the power failure
(in approximately 5 minutes after restoration of power).
VRF
Y-Series
VRF
Lineup
VRF
R2-Series
VRF
Zubadan
VRF
WY-Series
VRF
WR2-Series
VRF
S-Series
VRF
Indoor Units
Ventilation
Systems
Technologies and Functions
Remote Controller
Hot Water Solution
VRF
BC Controllers
VRF
S-Series
179
INDOOR UNIT FUNCTIONS
Summary of Contents for City Multi R2 Series
Page 1: ...CM20AN E NZ VRF City Multi Product Catalogue ...
Page 101: ...BC Controllers 101 ...
Page 112: ...Indoor Units VRF 112 ...
Page 114: ...Ceiling Cassette Type 4 Way Airflow Type 114 ...
Page 122: ...Ceiling Cassette Type 2 Way Airflow Type 122 ...
Page 128: ...Ceiling Concealed Type 128 ...
Page 150: ...Wall Mounted Type 150 ...
Page 154: ...Floor Standing Type 154 ...
Page 181: ...Ventilation Systems 181 ...
Page 190: ...Remote Controllers 190 ...