8. Connections of I/O Interface
8.1 Types of I/O Interface
94
8. Connections of I/O Interface
I/O interface is connected to RIO1/RIO2 of the control unit and RIO3 of the operation panel I/O unit.
8.1 Types of I/O Interface
There are four types of I/O interfaces as shown below.
Type
Explanation
Connection
Detailed
configuration
1 Remote I/O
Connecting with analog input,
analog output and manual pulse
generator is possible besides
DI/DO.
Refer to 8.2
Refer to 2.3.5
2 Scan
I/O
DI/DO input/output (32/32) is
possible besides scan type.
Refer to 8.3
Refer to 2.3.6
3 Card-sized I/O
55mm x 93mm in size.
Connector PCB must be
manufactured by the machine
tool builder when using card size
I/O card.
Refer to 8.4
Refer to 2.3.7
4 Expansion
I/O
DI/DO input/output (64/48) is
possible.
Refer to 8.5
Refer to 2.3.8