8. Connections of I/O Interface
8.2 Connecting with Remote I/O Unit
98
<Setting example 3>
FCUA-DX11 unit or FCUA-DX12 unit 4 units
Total No. of occupied stations: 8
(Maximum configuration)
2
3
4
5
6 7
Control unit
0
No. of occupied
stations: 2
1
MITSUBISHI
No. of occupied
stations: 2
No. of occupied
stations: 2
No. of occupied
stations: 2
(Note)
The assignment of each unit's input/output signal address will change with the setting of the channel No.
Refer to "PLC Interface Manual" for details.