Appendix 2. Cable
2.31 SH21 Cable
188
2.31 SH21 Cable
Cable type: SH21 cable
Application: Servo drive unit
SV1, SV2
Plug : 10120-3000VE
Shell : 10320-52F0-008
Recommended manufacturer : 3M
Connector name : SV1, SV2
Servo drive unit
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
0V
0V
SVTXD
SVTXD*
SVALM
SVALM*
SVRXD
SVRXD4
0V
0V
SVEMG
SVEMG*
+5V
Plug : 10120-3000VE
Shell : 10320-52F0-008
Recommended manufacturer : 3M
Control unit
Wire material :
UL20276 AWG28 10P
Recommended manufacturer :
Toyokuni Elecric Cable
0V
0V
SVTXD
SVTXD*
SVALM
SVALM*
SVRXD
SVRXD4
0V
0V
SVEMG
SVEMG*
+5V
FG
FG
(Note) Fold the cable shield over
the sheath, and wrap
copper foil tape over it.
Connect the wound
copper foil tape to the
connector's GND plate.
2.32 SH41 Cable
Cable type: SH41 cable
Application: Remote I/O
Connector : 1-178288-3
Contact : 1-175218-2 x 3
Recommended manufacturer:
Tyco Electronics AMP
RIO1,RIO2,RIO3 (CSH41)
Wire material : MVVS 3C x 0.5mm
2
(MIC 3C x 0.5mm
2
)
Recommended manufacturer: Takeuchi Densen
1
2
3
TXRX
TXRX*
0V
Connector name : RIO1,RIO2,RIO3 (CSH41)
1
2
3
TXRX
TXRX*
0V
Connector name : (CSH41)
Connector : 1-178288-3
Contact : 1-175218-2 x 3
Recommended manufacturer:
Tyco Electronics AMP
(Note)
(1) Protect both ends of the cable with insulated bushing.
(2) RIO1, RIO2 and RIO3 can be used commonly.
(3) Use this cable for short applications, such as bridging the remote I/O units in the same panel.
Normally use the FCUA-R211 cable with high noise withstand level.
(CSH41)
1
2
3
X