Appendix 4. Servo/Spindle Cable and Connector Specifications (MDS-D/DH)
4.2 Cable Connection Diagram
206
4.2 Cable Connection Diagram
CAUTION
1. Take care not to mistake the connection when manufacturing the detector
cable. Failure to observe this could lead to faults, runaway or fire.
2. When manufacturing the cable, do not connect anything to pins which have
no description.
4.2.1 Battery Cable
<DG21 cable connection diagram>
(Connection cable between drive unit and MDS-A-BT/MR-BAT (MDS-BTCASE)
1
2
9
1
PE
BT
LG
BT
LG
0.2mm
2
Drive unit side connector
Connector: DF1B-2S-2.5R
Contact: DF1B-2428SCA
Battery unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
Case
grounding
<Cable connection diagram between drive unit and FCU6-BTBOX-36>
1
2
+
-
FG
BT
LG
BT
LG
Case
grounding
0.2mm
2
Drive unit side connector
Connector: DF1B-2S-2.5R
Contact: DF1B-2428SCA
Battery unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
(Note) Connect the cable shield with
installation screw of unit.
(Note)
<DG22 cable connection diagram>
(Connection cable between drive unit and drive unit)
1
2
1
2
BT
LG
BT
LG
0.2mm
2
Drive unit side connector
Connector: DF1B-2S-2.5R
Contact: DF1B-2428SCA
Drive unit side connector
Connector: DF1B-2S-2.5R
Contact: DF1B-2428SCA