2. System Configuration
2.3 List of Configuration Units
7
2.3.3 Operation Panel I/O Unit: FCU7-DX670/FCU7-DX671/FCU7-DX770/FCU7-DX771
Type Function
Configuration
element
Details
FCU7-DX670
Sink/source input + sink
output
HN391
Mounting
bracket
G301 cable
G310 cable
Terminator R-TM
DI/DO = 32 points/32 points
(output 60mA)
Output insulation type (Note 1)
Display-main body relay I/F
Manual pulse generator 3ch
Emergency stop input
Remote I/O 1ch (160 points/160 points)
FCU7-DX671
Sink/source input + source
output
HN392
Mounting
bracket
G301 cable
G310 cable
Terminator R-TM
DI/DO = 32 points/32 points
(output 60mA)
Output insulation type (Note 1)
Display-main body relay I/F
Manual pulse generator 3ch
Emergency stop input
Remote I/O 1ch (160 points/160 points)
FCU7-DX770
Sink/source input + sink
output
HN391+HN396
Mounting
bracket
G301 cable
G310 cable
Terminator R-TM
DI/DO = 64 points/64 points
(output 60mA)
Output insulation type (Note 1)
Display-main body relay I/F
Manual pulse generator 3ch
Emergency stop input
Remote I/O 1ch (128 points/128 points)
FCU7-DX771
Sink/source input + source
output
HN392+HN397
Mounting
bracket
G301 cable
G310 cable
Terminator R-TM
DI/DO = 64 points/64 points
(output 60mA)
Output insulation type (Note 1)
Display-main body relay I/F
Manual pulse generator 3ch
Emergency stop input
Remote I/O 1ch (128 points/128 points)
(Note 1)
All points of the DO are insulated with a photo coupler. Thus, 24V must be input from an external
source for the DO output. Refer to"7.9 Connecting with Machine Operation Panel" for details.
(Note 2)
Operation panel I/O unit can be mounted on the back side of the keyboard unit
FCU7-KB021/KB022/KB041.
2.3.4 Keyboard Unit : FCU7-KB021/FCU7-KB022/FCU7-KB041
Type Function
Configuration
element
Details
FCU7-KB021
8.4-type display keyboard Escutcheon, key switch
Connect with G290 cable from display unit.
ONG layout for machining
center
Control card, G290 cable
Mounting method: Mount on front panel
FCU7-KB022
8.4-type display keyboard Escutcheon, key switch
Connect with G290 cable from display unit.
ONG layout for lathe
Control card, G290 cable
Mounting method: Mount on front panel
FCU7-KB041
10.4-type display keyboard Escutcheon, key switch
Connect with G290 cable from display unit.
ABC layout
Control card, G290 cable