Appendix 6. Precautions for Wiring M700 Series
6.6 Example of Handy Terminal Connections
254
Explanation of handy terminal functions
No. Name
Function/Specification
No. Name
Function/Specification
(1) LCD Monochrome display with backlight
192(W) x 64(H) dots
(7) HOST Host interface connector
(DDK:17JE-23250-02(D8A6))
(2) SW1 Emergency stop switch
Contact rating/Contact: 24VDC, 1A
Contact configuration: 2b contacts
(IDEC Corporation:
HA1E-V2S2VR)
(8)
- Host
interface
cable
(5m)
(3)
-
Membrane switch (Note)
(9)
-
Simplified hand strap
(IDEC Corporation: HG9Z-PS1)
(4) SW2 Enable
switch
Contact rating/Contact: 24VDC, 50mA
Contact configuration:
3 position contact x 2
(OFF-ON-OFF)
(IDEC Corporation: HE3B-M2)
(10)
- Panel
hanging
fitting
(IDEC Corporation: HG9Z-TK1)
(5) SW4 Manual pulse generator
Output: Open collector
4.7k
Ω
pull-up resistor is connected.
(TOKYO SOKUTEIKIZAI CO., LTD:
RE19PH50C16RR)
(11)
- Serial
number
plate
(6) SW6 Selector
switch
(Note) Cautions about simultaneous pressing of multiple switches (impossible): When 3 or more switches