3. General Specifications (Environment Conditions)
3.1 Environment Conditions in Operation Box
11
3. General Specifications (Environment Conditions)
3.1 Environment Conditions in Operation Box
Unit name
Display unit (Note 5)
(Including keyboard and front IC card I/F unit)
Operation panel
I/O unit
Item
Type
FCU7
-DA201
FCU7
-DA211
FCU7
-DA315
FCU7
-DA415/
DA445
FCU7
-DA335
FCU7
-DA435
FCU7
-DX670/
DX671
FCU7
-DX770/
DX771
During
operation
0 to 55°C
(Note 1)
Ambient
temperature
During
storage
-20 to 60°C
Long
term
10 to 75% RH (with no dew condensation)
Ambient
humidity
Short
term
10 to 95% RH (with no dew condensation) (Note 2)
Vibration
resistance
During
operation
4.9m/s
2
[0.5G] or less
Shock
resistance
During
storage
29.4m/s
2
[3.0G] or less
General
specifi-
cations
Working
atmosphere
No corrosive gases, dust or oil mist
Power
voltage
24VDC ± 5%, ripple noise 240mV (P-P)
Power
capacity
(max.)
2A
(max.)
2.5A
(max.)
3A
(max.)
2.8A
(max)
3.3A
(max)
0.5A
(Note 3)
2.9A
(Max.)
(Note 4)
0.7A
(Note 3)
5.0A
(max.)
(Note 4)
Required
power
specifi-
cations
Instantaneous
stop tolerance
time
AC: 20ms or less (when using external power supply unit PD25/PD27),
24VDC: 2ms or less
Heating value
25W
(max.)
15W
(Typ)
46W
(max.)
37W
(Typ)
60W
(max.)
48W
(Typ)
53.5W
(max)
43W
(Typ)
67.5W
(max)
54W
(Typ)
30W
(max.)
(Note 4)
50W
(max.)
(Note 4)
Display
3.5 kg
4.0 kg
6kg
Others
Mass
Others
Keyboard unit
FCU7-KB021/KB022
: 1.0 kg
FCU7-KB041
: 1.5 kg
Front IC card I/F unit
FCU7-EP102-1
: 0.3 kg
Hard disk unit
FCU7-HD001-1 :
0.6kg
0.6 kg
(Note 1)
The display grade (contrast/brightness) will drop at 45°C or more.
(Note 2)
The period is within one month.
(Note 3)
Current consumed by control circuit section.
(Note 4)
Differs according to the number of machine input operation points and the load and number of
points connected to the machine output. The maximum value applies when all points are ON.
(Note 5)
Panel front is equivalent to IP65F.