4. Outline Drawing
4.3 Operation Panel I/O Unit
32
4.3 Operation Panel I/O Unit
4.3.1 FCU7-DX670 / FCU7-DX671 / FCU7-DX770 / FCU7-DX771 Outline Drawing
105 (S p ace re quire d fo r w iring )
116
167
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(10 )
(11 )
(9)
(8)
(12 )
Explanation of Operation panel I/O unit and connector functions
No.
Connector
name
Function
(1) NCRST NC keyboard
→
Control unit
Reset I/F (DI: 1 point used)
(2) DCIN
24VDC
input
(3) EMGIN
External emergency stop input for
operation panel
(4) OPI
Control unit connection I/F
(5) RIO3
Remote
I/O
Connection I/F for 3rd channel
expansion
No.
Connector
name
Function
(6)
CG32
DO: 32 points 60mA
(7)
CG31
DI: 32 points
(8)
PCLAN
Display side LAN connection I/F
(9)
MPG
Manual pulse generator 3ch
(10)
CG34
DO: 32 points 60mA
(11)
CG33
DI: 32 points
(12)
FG
RIO3 cable clamp FG