6. Connections of Control Unit
6.6 Connecting with Optical Communication Servo Drive Unit
61
6.6 Connecting with Optical Communication Servo Drive Unit
(1) Connect servo drive unit MDS-D/DH series and MDS-D-SVJ3/SPJ3 series to the connector OPT1.
For the details on servo drive unit, refer to the following section and manuals:
"10. Basic Wiring for Servo Drive Unit"
"MDS-D Series Specifications Manual IB-1500011(ENG)"
"MDS-DH Series Specifications Manual IB-1500003(ENG)"
"MDS-D/DH Series Instruction Manual IB-1500025(ENG)"
"MDS-D-SVJ3/SPJ3 Series Specifications Manual IB-1500158(ENG)"
"MDS-D-SVJ3/SPJ3 Series Instruction Manual IB-1500193(ENG)"
MITSUBIS
HI
OPT1
G396 cable
NC control unit
Servo drive unit
(MDS-D/DH)
CN1A
CN1B
Servo drive unit
(MDS-D/DH)
CN1A
CN1B
Reinforced
sheath
G395 / G380 cable
OR
(Note 1)
Binding the cables too tight with tie-wraps could result in an increased loss or a disconnection.
Use a cushioning material such as sponge or rubber when bundling the cables and fix so that
the cables do not move.
Recommended clamp material: CKN-13SP KITAGAWA INDUSTRIES
(Note 2)
Never bundle the cables with vinyl tape. The plasticizing material in the vinyl tape could cause
the cable reinforced sheath section to break.