6. Connections of Control Unit
6.11 Connecting with Synchronous Feed Encoder/Manual Pulse Generator
72
6.11 Connecting with Synchronous Feed Encoder/Manual Pulse Generator
Synchronous feed encoder (1ch) or 5V power supply type manual pulse generator (2ch) can be connected.
MITSUBISHI
5V 0V A B
G023 cable
NO.1
5V manual pulse generator
(Rear view)
G024 cable
NO.1
NO.2
When connecting one 5V
manual pulse generator
When connecting two 5V
manual pulse generators
5V 0V A B
5V 0V A B
R050 cable
R054 cable
Synchronous feed encoder
OSE1024-3-15-68
5V manual pulse generator
(Rear view)
ENC
<Related items>
Cable drawing: "Appendix 2 (FCUA-R050/R054 Cable, G023/G024)"
Connector pin assignment: "Appendix 3 (ENC connector)"
Refer to the section "7.6.2 Connecting with 5V Manual Pulse Generator" for 5V manual pulse generator's
input conditions and input/output circuit example.
When using synchronous feed encoder and manual pulse generator at the same time, the cables must be
prepared by the machine tool builder.