GCH15010
79
12
SERVICE AND MAINTENANCE
Engineers Forms
Commissioning / Field settings record sheet
Hot water (DHW)
Heating
Compensation
curve
Adjust
Holiday
Initial settings
Service menu
*1 The settings related to Zone2 can be switched only when 2 zone temperature control is enabled (when DIP SW2-6 and SW 2-7 are ON).
*2 Valid only when operating in Room temp. control mode.
*3 On: the function is active; Off: the function is inactive.
*4 If asterisk (**) is chosen freeze stat function is deactived. (i.e. primary water freeze risk)
*5 The settings related to Zone2 can be switched only when 2-Zone valve ON/OFF control is active.
Hi flow temp.
set point
Field
setting Notes
Should settings be changed from default, please enter and record new setting in ‘Field Setting’ column. This will ease resetting in the future should the system use change
or the circuit board need to be replaced.
Main
Option
Setting
Main controller screen
Room temp
20°C
20°C
45°C
0°C
—
—
On
On
—
55°C
15°C
60 mins
30 mins
Normal
í&
50°C
35°C
25°C
—
—
Non active
Active
15°C
15°C
35°C
°C
Off
Off
hh:mm
TH1
TH1
Zone1
0°C
0°C
0°C
0°C
0°C
0°C
On
10 mins
On
Default
setting
Parameters
Zone1 heating room temp.
Zone1 heating flow temp.
Zone1 heating compensation curve
Zone2 heating room temp. *5
Holiday mode
Forced DHW operation
DHW
Heating
Energy monitor
DHW supply max. temp.
DHW supply temp. drop
DHW max. operation time
DHW mode restriction
DHW storage volume
Zone1 operation mode
Zone1 outdoor ambient temp.
Zone1 flow temp.
Zone1 flow temp.
Zone1 flow temp.
Zone1 outdoor ambient temp.
Zone1 outdoor ambient temp.
DHW
Zone1 heating flow temp.
Heating
Zone1 heating room temp.
Zone2 heating room temp. *5
°C/°F
Summer time
Temp. display
Time display
Room sensor settings for Zone1
Room sensor settings for Zone2 *1
Room RC zone select *1
Thermistor
adjustment
Auxiliary settings
THW1
THW2
THW3
THW4
THW5A
THW5B
Economy settings
for pump.
10°C - 30°C
10°C - 30°C
25°C - 60°C
í&&
Active/Non active/Set time
On/Off
On/Off/Timer
On/Off/Timer
Consumed electric energy/Produced energy
40°C - 70°C
15°C - 30°C
30 - 120 mins
30 - 120 mins
Normal/Energy save
Room temp/Flow temp/Compensation curve
í&
-
33°C
25°C – 60°C
í&&
25°C - 60°C
í&&
25°C - 60°C
Active/Non active
Active/Non active
10°C - 30°C
10°C - 30°C
25°C - 60°C
°C/°F
On/Off
Room/Tank/Room&tank /Off
hh:mm/hh:mm AM/AM hh:mm
7+0DLQ5&5RRP5&³
Time/Zone”
7+0DLQ5&5RRP5&³
Time/Zone”
Zone1/Zone2
í&&
í&&
í&&
í&&
í&&
í&&
On/Off *3
Delay (3 - 60 mins)
Space heating: On (used)/Off (not used)
Electric heater delay timer (5
PLQV
30 mins
Pump speed
Pump speed(1 - 5)
Standard/Heater
Operation
settings
Min.temp.(25 - 45°C)
Max.temp.(35 - 60°C)
Mode(Normal /Fast)
Interval(10 - 60min)
On/Off *3
Mode(Auto/Manual)
/RZHUOLPLWíí&
)ORZUDWH/PLQ
8SSHUOLPLW&
)
Outdoor ambient temp. (3 - 20°C) / **
Energy
monitor
settings
0 - 30kW
0 - 200W or ***(factory fitted pump)
0.1/1/10/100/1000 pulse/kWh
0.1/1/10/100/1000 pulse/kWh
í
4
Standard
40°C
50°C
Normal
10 mins
On
Auto
-5°C
7L/min
&
5°C
2kW
***
1 pulse/kWh
1 pulse/kWh
Lo flow temp.
set point
Electric heater
(Heating)
Flow temp.range
*2
Room temp.control
*2
Heat pump thermo
diff.adjust *2
Flow rate settings
Booster heater 1
capacity
Pump 1
Heat source setting
Heating operation
Freeze stat function *4
Electric heater
capacity
Delivered energy adjustment
Water pump input
Electric energy meter
Heat meter