12
FTC4 Installation Manual
9
Ecodan
®
Technical Data
5kW Unit
8.5kW Unit
14kW Unit
Model PUHZ-W50VHA-BS PUHZ-W85VHA(2)-BS PUHZ-HW140VHA(2)-BS/
PUHZ-HW140YHA (2)-BS
Dimensions (mm) Width 950 950 1020
Depth 330+30* 330+30* 330+30*
Height 740 943 1350
Weight (kg) 64 77 134 / 148
Airflow (m3/min) 50 55 100
Nominal sound level (dBA) 45
◊
48
◊
53
◊
Low noise mode (dBA) @ 7°C 40 42 46
Guaranteed operating range (Outdoor) - 15 ~ +35°C - 20 ~ +35°C - 25 ~ +35°C
Electrical Supply 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz / 380-415v, 50Hz
Phase Single Single Single / 3 Phase
Running current (A) [Max] 5.4 [13] 10.3 [23] 14.9 [35] / 5.1 [13]
Fuse Rating (MCB sizes BS EN 60947-2) (A) 16 25 40 / 16
Heating A2/W35 Capacity (kW) 5.0 8.5 14
COP 3.13 3.17 3.11
Power Input (kW) 1.6 2.68 4.52
Nominal Flow Rate (L/min) 14.3 25.8 40.1
Heating A7/W35 Capacity (kW) 5.0 9.0 14.0
COP 4.1 4.18 4.25
Power Input (kW) 1.22 2.15 3.29
Nominal Flow Rate (L/min) 14.3 25.8 40.1
Primary Flow Rate Maximum (L/min) 14.3 25.8 40.1
Minimum (L/min) 6.5 10 17.9
* Grille
◊
At distance of 1m from the outdoor unit
Eco label models denoted by (2) after product
Table 1.2
Summary of Contents for Ecodan HUS210FTC4ST
Page 2: ......
Page 8: ...5 Pipework Configuration 8 FTC4 Installation Manual ...
Page 20: ...20 FTC4 Installation Manual 14 Ecodan Only System Schematic ...
Page 83: ......