3.Product Specifications

   

For detail specifications which do not appear in the specification comparison charts contained herein, see the user's manual supplied with the MELSEC-Q Series or MELSEC iQ-R Series Module you use. Also, check 
that the specifications of the connected devices meet the specifications of the MELSEC-Q Series or MELSEC iQ-R Series Module.

 

 

 

Conversion Adapter 

Model 

Before replacement 

Module Model 

No. of 

in/output points 

After replacement 

MELSEC-Q Series Module Model 

 

After replacement 

MELSEC iQ-R Series Module Model 

 

Conversion 

Adapter 

Weight (g) 

No. of modules 

No. of modules 

ERNT-2JQ212S 

JW-212S/JW-212SA 

16 

QY40P 

QY50 
QY70 

RY40NT5P 

80 

JW-212N/JW-212NA 

16 

QX80 

(*1) 

- 

JW-214N/JW-214NA 

16 

*1 The Conversion Adapter, ERNT-2JQ210NS, allows to replace the current module with the MELSEC iQ-R Series Module, RX40C7. 

 

 

(1) In the case of JW-212S/JW-212SA  →  QY40P/QY50/QY70 or RY40NT5P

 

 

Signal

Name

Internal circuit diagram of 

ERNT-2JQ212S

New Satellite

JW Series

Terminal block

MELSEC-Q Series

or

MELSEC iQ-R Series

Terminal block

TB1

TB2 TB3

TB4 TB5

TB6 TB7

TB8 TB9

TB10 TB11

TB12 TB13

TB14 TB15

TB16 TB17

TB18

TB1

TB2 TB3

TB4 TB5

TB6 TB7

TB8 TB9

TB10 TB11

TB12 TB13

TB14 TB15

TB16 TB17

TB18 TB19

TB20

TB1

TB2

TB3

TB4

TB5

TB6

TB7

TB8

TB9

TB10

TB11

TB12

TB13

TB14

TB15

TB16

TB17

TB18

TB1

TB2

TB3

TB4

TB5

TB6

TB7

TB8

TB9

TB10

TB11

TB12

TB13

TB14

TB15

TB16

TB17

TB18

L
L
L
L
L
L
L
L

L
L
L
L
L
L
L
L

Y00

Y01

Y02

Y03

Y04

Y05

Y06

Y07

Y08

Y09

Y0A

Y0B

Y0C

Y0D

Y0E

Y0F

DC

COM

0A

1A

2A

3A

4A

5A

6A

7A

0B

1B

2B

3B

4B

5B

6B

7B

TB1

TB2

*1

*2

Terminal 

No.

Power 

supply

(※)

Power 

supply

(※)

※Power supply

QY70

5/12VDC

12/24VDC

QY50

QY40P

External power supply connector

(conversion adapter accessory)

Terminal 

No.

Signal

Name

RY40NT5P

 

 

 

Precautions for wiring

 

 

Because the switch concerned causes the number of points per common to change 
from 8 (two circuits) to 16 (one circuit), an alteration to the wiring is required if the 
commons on the existing modules have been used in separation from each other. 

 

Additional supply of voltages (5/12/24VDC) which are the same as electrical loads to 
the terminal numbers TB1 and TB2 of the external power supply connector is 
required. 

 

[Using the same power supply as 

the loads] 

[Using the power supply 
different from the loads] 

DC (+) side 

Wiring required 

Wiring required 

COM (-) side 

Wiring not required

*

 

Wiring required 

*There is no problem even if wiring is carried out. 

< Specification Comparison >

 

Model 

 

Specifications 

New Satellite JW Series 

MELSEC-Q Series 

MELSEC iQ-R 

Series 

JW-212S 

Sink type 

JW-212SA 

Sink type 

QY40P 

Sink type 

QY50 

Sink type 

QY70 

Sink type 

RY40NT5P 

Sink type 

No. of output points 

16 points 

16 points 

16 points 

16 points 

16 points 

16 points 

Rated load voltage 

5/12/24VDC 

(4.75 to 27VDC) 

5/12/24VDC 

(4.75 to 27VDC) 

12/24VDC 

(+20%/-15%) 

12/24VDC 

(+20%/-15%) 

5/12VDC 

(+25%/-10%) 

12/24VDC 

(10.2 to 28.8VDC) 

Maximum load current 

0.5A/point 

2A/common 

0.5A/point 

2A/common 

0.1A/point 

1.6A/common 

0.5A/point 

4A/common 

16mA/point 

256mA/common 

0.5A/point 

Pilot Duty 

5A/common 

Maximum inrush 
current 

1A, 100ms 

1A, 100ms 

0.7A, 10ms 

or less 

4A, 10ms 

or less 

40mA, 10ms 

or less 

Current is to be 
limited by the 
overload protection 
function 

Leakage current at OFF  0.2mA or lower  0.2mA or lower  0.1mA or lower  0.1mA or lower 

― 

0.1mA or lower 

Maximum voltage drop 
at ON 

1.2VDC 

(MAX.) 0.3A 

1.2VDC 

(MAX.)0.3A 

0.2VDC 

(MAX.)0.1A 

0.3VDC 

(MAX.)0.5A 

V

OL

: 0.3VDC 

0.2VDC(TYP.) 0.5A 

0.3VDC(MAX.) 0.5A 

Response 
time 

OFF to ON 

1ms or less 

(resistive load) 

1ms or less 

(resistive load) 

1ms or less 

1msor less 

0.5ms or less 

0.5ms or less 

ON to OFF 

1ms or less 

(resistive load) 

1ms or less 

(resistive load) 

1ms or less 
(rated load, 

resistive load) 

1ms or less 
(rated load, 

resistive load) 

0.5ms or less 

(resistive load) 

1ms or less 

(rated load, 

resistive load) 

Surge suppressor 

Zener diode 

Zener diode 

Zener diode 

Zener diode 

None 

Zener diode 

Fuse 

3A 

(unchangeable) 

3.15A 

(unchangeable) 

None 

6.7A 

(unchangeable) 

1.6A 

(unchangeable) 

None 

Isolation method 

Photocoupler 

Photocoupler 

Photocoupler 

Photocoupler 

Photocoupler 

- 

Common terminal 
arrangement 

8 points/common 

(2 circuits) 

8 points/common 

(2 circuits) 

16 points 

/common 

16 points 

/common 

16 points 

/common 

16 points 

/common 

External connections 

18-point 

terminal block 

18-point 

terminal block 

18-point 

terminal block 

18-point 

terminal block 

18-point 

terminal block 

18-point 

terminal block 

Make sure the            section of the above table meets the specification of the machines and equipment connected to the MELSEC-Q Series 
Module. 

 

The following table lists the specifications of wires applicable to the external power supply connector (accessory). 

Item 

Specifications 

Applicable wire size 

0.14 to 1.5mm

2

 (24 to 16AWG) 

Type 

Stranded wire/single wire 

Material 

Copper 

Screw tightening torque 

0.22 to 0.25N・m 

 

 

4.Mounting and Installation 

4.1  Handling Precautions 

(1) Before attempting to install the Unit or carry out the necessary wiring, make certain that the external power supply, used in the system, is shut off on all three phases. Failure to do so 

may result in electric shock or damage to the product. 

(2) Do not touch live terminals. There is a danger of electric shock or malfunction.

 

(3) Do not modify the Conversion Adapter or take it apart. Doing so will cause failure, malfunction, personal injury, or fire.

 

(4) Do not touch the energized part of the Conversion Adaptor directly. Contact will cause malfunction or failure in the system.

 

(5) Fasten the Conversion Adapter and the Mounting Bracket securely with retaining screws, and tighten the screws by applying torque within specified limits. Loose screws can lead to the 

dropping of the Conversion Adapter, or Mounting Bracket, possibly causing breakage thereof.    Excessive tightness of the screws can lead to breakage of the screws, Converter Adaptor, 
Mounting Bracket, or MELSEC-Q Series or MELSEC iQ-R Series Module, possibly causing the dropping, shorting, and malfunction thereof.

 

(6) Use care to prevent foreign materials including cuttings and wiring debris from entering the Conversion Adapter or the MELSEC-Q Series or MELSEC iQ-R Series Module. These will be 

cause for fire, failure or malfunction.

 

(7) Do not drop the Conversion Adapter and Mounting Bracket or do not give a strong impact to it. This will cause damage.

 

 

4.2

 

Use Precautions

 

Item 

New Satellite JW Series  →  MELSEC-Q Series 

New Satellite JW Series  →  MELSEC iQ-R Series 

U

se

 P

re

ca

ut

io

ns

 

W

id

th

 d

im

en

sio

of

 m

od

ule

 

Because the module is reduced in width dimension  (35mm→27.4mm)  and thus in 
area available for wiring, check dimensional data before installing the module. 

27.4

35

Unit:mm

New Satellite 

JW Series

MELSEC-Q

Series

Upgrade Tool

+

 

Because the module is reduced in width dimension  (35mm→27.8mm)  and thus in 
area available for wiring, check dimensional data before installing the module. 

27.8

35

Unit:mm

New Satellite 

JW Series

MELSEC iQ-R

Series

Upgrade Tool

+

 

D

ep

th

 d

im

en

sio

Because the module is increased in depth dimension, check dimensional data before 

installing the module. 

New Satellite 

JW Series

Unit:mm

MELSEC-Q

Series

Upgrade Tool

+

110

137.5

UP

27.5mm

(18.5mm)

(128.5)

 

 

*The each depth dimension is measured from the panel surface.

 

The value in 

parentheses (shorter by 9mm) is the dimension when the AnS-size Q Series Large 
Type Base Unit is not used. 

New Satellite JW Series: Base Unit + Input/output  Terminal block   
MELSEC-Q  Upgrade Tool: Q Series Large Type Base Unit (AnS Series Size)   

+ Input/output  Conversion Adapter   
+ Terminal block 

Because the module is increased in depth dimension, check dimensional data before 
installing the module. 

New Satellite

JW Series

MELSEC iQ-R

Series

Upgrade Tool

+

110

169.6

UP

59.6mm

Unit:mm

 

 
*The each depth dimension is measured from the panel surface. 
New Satellite JW Series: Base Unit + Input/output  Terminal block   

MELSEC iQ-R  Upgrade Tool: Base Unit + Input/output Module   

+ Conversion A Terminal block 

In

te

rfe

re

nc

e o

f t

he

 te

rm

in

al 

blo

ck

 

When  mounting  the  one  of  following  Conversion  Adapter  on  the  right  side  of  the 
Conversion Adapter, it is recommended to use the AnS-size Q Series Large Type Base 
Unit  (Q□□BLS,  Q□□BLS-D)  manufactured  by  Mitsubishi  Electric  so  that  the 
Conversion  Adapter  does  not  interfere  with  the  terminal  block  or  connector  of  the 
existing module. 
When using the MELSEC-Q Series Base Unit, leave one slot open between them. 
 

Conversion Adapter : ERNT-2JQ210NS (Installed to the QY22),   

ERNT-2JQ234N264N, ERNT-2JQ232S262S 

Input / Output 

Module

Conversion Adapter

Terminal block of

the New Satellite JW

 Series

The Conversion Adapter interferes with the 

terminal block of the New Satellite JW Series.

Leave one slot 

open.

Conversion Adapter

・ERNT-2JQ210NS

   (Installed to the QY22)

・ERNT-2JQ234N264N

・ERNT-2JQ232S262S

Input / Output 

Module

Terminal block or connector of

the New Satellite JW Series

 

 

No constraint

 

4.3

 

Installation Environment

 

Refer to the manual supplied with the MELSEC-Q Series or MELSEC iQ-R Series module you use. 

・MELSEC-Q Series: QCPU User’s Manual (SH-080483ENG) 

・MELSEC iQ-R Series: Safety Guidelines (IB-0800525E) 

*1

 

*2

 

(2) In the case of JW-212N/JW-212NA/JW-214N/JW-214NA  →  QX80

 

Internal circuit diagram of 

ERNT-2JQ212S

New Satellite

JW Series

Terminal block

MELSEC-Q Series

Terminal block

TB1

TB2 TB3

TB4 TB5

TB6 TB7

TB8 TB9

TB10 TB11

TB12 TB13

TB14 TB15

TB16 TB17

TB18

TB1

TB2 TB3

TB4 TB5

TB6 TB7

TB8 TB9

TB10 TB11

TB12 TB13

TB14 TB15

TB16 TB17

TB18 TB19

TB20

TB1

TB2

TB3

TB4

TB5

TB6

TB7

TB8

TB9

TB10

TB11

TB12

TB13

TB14

TB15

TB16

TB17

TB18

L
L
L
L
L
L
L
L

L
L
L
L
L
L
L
L

24VDC

Y00

Y01

Y02

Y03

Y04

Y05

Y06

Y07

Y08

Y09

Y0A

Y0B

Y0C

Y0D

Y0E

Y0F

NC

COM

0A

1A

2A

3A

4A

5A

6A

7A

0B

1B

2B

3B

4B

5B

6B

7B

TB1

TB2

External power 

supply is not 

requierd.

Positive common is not available.

Terminal 

No.

Signal

Name

Signal

Name

*1

*2

External power supply connector

(conversion adapter accessory)

TB2

TB3

TB4

TB5

TB6

TB7

TB8

TB9

TB10

TB11

TB12

TB13

TB14

TB15

TB16

TB17

TB18

Terminal 

No.

TB1

*3

 

Precautions for wiring

 

 

Because the switch concerned causes the number of points per common to 
change from 8 (two circuits) to 16 (one circuit), an alteration to the wiring is 
required if the commons on the existing modules have been used in separation 
from each other. 

 

Negative common is available. (Positive common is not available.) 

 

External power supply to the terminal numbers TB1 and TB2 on the external 
power supply connector is not required.

 

< Specification Comparison >

 

Model 

 
 
 
 

Specifications 

New Satellite JW Series 

MELSEC-Q 

Series 

JW-212N 

JW-212NA 

Positive/Negative 

shared common type 

JW-214N 

JW-214NA 

Positive/Negative 

shared common type 

QX80 

Negative 

common type 

No. of input points 

16 points 

16 points 

16 points 

Rated input voltage 

12/24VDC 

(10.5 to 26.4VDC) 

12/24VDC 

(10.5 to 26.4VDC) 

24VDC 

(+20%/-15%) 

Rated input current 

Approx. 7.5mA

(24VDC) 

Approx. 3.5mA

(12VDC) 

Approx. 7.5mA

(24VDC) 

Approx. 3.5mA

(12VDC) 

Approx. 4mA 

Input impedance 

Approx. 3.3kΩ 

Approx. 3.3kΩ 

Approx. 5.6kΩ 

Inrush current 

― 

― 

― 

Operating 
voltage/ 
current 

ON 

10.5V/3mA 

10.5V/3mA 

19V/3mA 

OFF 

5V/1.5mA 

5V/1.5mA 

11V/1.7mA 

Response 
time 

OFF to ON 

10ms or less 

0.5ms or less 

1/5/10/20/70ms 

or less 

ON to OFF 

10ms or less 

1.5ms or less 

1/5/10/20/70ms 

or less 

Isolation method 

Photocoupler 

Photocoupler 

Photocoupler 

Common terminal 
arrangement 

8 points/common 

(2 circuits) 

8 points/common 

(2 circuits) 

16 points/common 

External connections 

18-point   

terminal block 

18-point   

terminal block 

18-point 

terminal block 

Make sure the            section of the above table meets the specification of the machines and 
equipment connected to the MELSEC-Q Series Module. 

 

*1

 

*2

 

*3

 

Reviews: