124
PA
R
A
M
E
T
E
R
2
124
PARAMETER
PARAMETER
—
71
Applied motor
0 to 8, 13 to 18, 20, 23, 24,
30, 33, 34, 40, 43, 44, 50, 53,
54
1
0
71
47
C7
0
{
{
{
{
{
{
{
{
{
{
—
72
PWM frequency selection
0 to 15/0 to 6, 25
1
2
72
48
C8
0
{
{
{
{
{
{
{
{
{
{
—
73
Analog input selection
0 to 7, 10 to 17
1
1
73
49
C9
0
{
{
{
{
×
{
{
{
×
{
—
74
Input filter time constant
0 to 8
1
1
74
4A
CA
0
{
{
{
{
×
{
{
{
{
{
—
75
Reset selection/disconnected PU detection/
PU stop selection
0 to 3, 14 to 17
1
14
75
4B
CB
0
{
{
{
{
{
{
{
{
×
×
—
76
Fault code output selection
0, 1, 2
1
0
76
4C
CC
0
{
{
{
{
{
{
{
{
{
{
77
Parameter write selection
0, 1, 2
1
0
77
4D
*6
CD
*6
0
{
{
{
{
{
{
{
{
{
{
78
Reverse rotation prevention selection
0, 1, 2
1
0
78
4E
CE
0
{
{
{
{
{
{
{
{
{
{
79 Operation mode selection
0, 1, 2, 3, 4, 6, 7
1
0
79
4F
*6
CF
*6
0
{
{
{
{
{
{
{
{
{
{
M
o
to
r c
onst
ant
s
80
Motor capacity
0.4 to 55kW, 9999/
0 to 3600kW, 9999
0.01/0.1kW
9999
80
50
D0
0
×
{
{
{
{
{
{
{
{
{
81
Number of motor poles
2, 4, 6, 8, 10, 12, 14, 16, 18,
20, 9999
1
9999
81
51
D1
0
×
{
{
{
{
{
{
{
{
{
82
Motor excitation current
0 to 500A, 9999/
0 to 3600A, 9999
0.01/0.1A
9999
82
52
D2
0
×
{
{
{
{
{
{
{
×
{
83
Rated motor voltage
0 to 1000V
0.1V
200/400V
83
53
D3
0
×
{
{
{
{
{
{
{
{
{
84
Rated motor frequency
10 to 120Hz
0.01Hz
60Hz
84
54
D4
0
×
{
{
{
{
{
{
{
{
{
89
Speed control gain (Advanced magnetic
flux vector)
0 to 200%, 9999
0.1%
9999
89
59
D9
0
×
{
×
×
×
×
×
{
×
{
90
Motor constant (R1)
0 to 50
Ω
,
9999/
0 to 400m
Ω
, 9999
0.001
Ω
/
0.01m
Ω
9999
90
5A
DA
0
×
{
{
{
{
{
{
{
×
{
91
Motor constant (R2)
0 to 50
Ω
,
9999/
0 to 400m
Ω
,
9999
0.001
Ω
/
0.01m
Ω
9999
91
5B
DB
0
×
{
{
{
{
{
{
{
×
{
92
Motor constant (L1)
0 to 50
Ω
(0 to 1000mH), 9999/
0 to 3600m
Ω
(0 to 400mH), 9999
0.001
Ω
(0.1mH)/
0.01m
Ω
(0.01mH)
9999
92
5C
DC
0
×
{
{
{
{
{
{
{
×
{
93
Motor constant (L2)
0 to 50
Ω
(0 to 1000mH), 9999/
0 to 3600m
Ω
(0 to 400mH), 9999
0.001
Ω
(0.1mH)/
0.01m
Ω
(0.01mH)
9999
93
5D
DD
0
×
{
{
{
{
{
{
{
×
{
94
Motor constant (X)
0 to 500
Ω
(0 to 100%), 9999/
0100
Ω
(0 to 100%), 9999
0.01
Ω
(0.1%)/
0.01
Ω
(0.01%)
9999
94
5E
DE
0
×
{
{
{
{
{
{
{
×
{
95
Online auto tuning selection
0 to 2
1
0
95
5F
DF
0
×
{
{
{
{
{
{
{
{
{
96
Auto tuning setting/status
0, 1, 101
1
0
96
60
E0
0
×
{
{
{
{
{
{
{
×
{
A
d
jus
table 5
point
s V
/F
100
V/F1(first frequency)
0 to 400Hz, 9999
0.01Hz
9999
100
00
80
1
{
×
×
×
×
×
×
{
{
{
101
V/F1(first frequency voltage)
0 to 1000V
0.1V
0V
101
01
81
1
{
×
×
×
×
×
×
{
{
{
102
V/F2(second frequency)
0 to 400Hz, 9999
0.01Hz
9999
102
02
82
1
{
×
×
×
×
×
×
{
{
{
103
V/F2(second frequency voltage)
0 to 1000V
0.1V
0V
103
03
83
1
{
×
×
×
×
×
×
{
{
{
104
V/F3(third frequency)
0 to 400Hz, 9999
0.01Hz
9999
104
04
84
1
{
×
×
×
×
×
×
{
{
{
105
V/F3(third frequency voltage)
0 to 1000V
0.1V
0V
105
05
85
1
{
×
×
×
×
×
×
{
{
{
106
V/F4(fourth frequency)
0 to 400Hz, 9999
0.01Hz
9999
106
06
86
1
{
×
×
×
×
×
×
{
{
{
107
V/F4(fourth frequency voltage)
0 to 1000V
0.1V
0V
107
07
87
1
{
×
×
×
×
×
×
{
{
{
108
V/F5(fifth frequency)
0 to 400Hz, 9999
0.01Hz
9999
108
08
88
1
{
×
×
×
×
×
×
{
{
{
109
V/F5(fifth frequency voltage)
0 to 1000V
0.1V
0V
109
09
89
1
{
×
×
×
×
×
×
{
{
{
T
h
ird f
unct
ion
110
Third acceleration/deceleration time
0 to 3600/360s, 9999
0.1/0.01s
9999
110
0A
8A
1
{
{
{
{
∆
{
{
{
{
{
111
Third deceleration time
0 to 3600/360s, 9999
0.1/0.01s
9999
111
0B
8B
1
{
{
{
{
∆
{
{
{
{
{
112
Third torque boost
0 to 30%, 9999
0.1%
9999
112
0C
8C
1
{
×
×
×
×
×
×
{
{
{
113
Third V/F (base frequency)
0 to 400Hz, 9999
0.01Hz
9999
113
0D
8D
1
{
×
×
×
×
×
×
{
{
{
114
Third stall prevention operation current
0 to 220%
0.1%
150%
114
0E
8E
1
{
{
×
×
×
×
×
{
{
{
115
Third stall prevention operation frequency
0 to 400Hz
0.01Hz
0
115
0F
8F
1
{
{
×
×
×
×
×
{
{
{
116
Third output frequency detection
0 to 400Hz
0.01Hz
60Hz
116
10
90
1
{
{
{
{
{
{
{
{
{
{
P
U
c
o
nnect
o
r
comm
unicat
io
n
117
PU communication station number
0 to 31
1
0
117
11
91
1
{
{
{
{
{
{
{
{
{
{
118
PU communication speed
48, 96, 192, 384
1
192
118
12
92
1
{
{
{
{
{
{
{
{
{
{
119
PU communication stop bit length
0, 1, 10, 11
1
1
119
13
93
1
{
{
{
{
{
{
{
{
{
{
120
PU communication parity check
0, 1, 2
1
2
120
14
94
1
{
{
{
{
{
{
{
{
{
{
121
Number of PU communication retries
0 to 10, 9999
1
1
121
15
95
1
{
{
{
{
{
{
{
{
{
{
122
PU communication check time interval
0, 0.1 to 999.8s, 9999
0.1s
9999
122
16
96
1
{
{
{
{
{
{
{
{
{
{
123
PU communication waiting time setting
0 to 150ms, 9999
1
9999
123
17
97
1
{
{
{
{
{
{
{
{
{
{
124
PU communication CR/LF selection
0, 1, 2
1
1
124
18
98
1
{
{
{
{
{
{
{
{
{
{
—
125 Terminal 2 frequency setting gain frequency 0 to 400Hz
0.01Hz
60Hz
125
19
99
1
{
{
{
{
×
{
{
{
×
{
Fu
nct
io
n
[Pr.]
Name
Setting Range
Minimum Setting
Increments
Initial Value
Refer to
Page
[Pr.]
Option
Instruction Code
Control Mode-based Correspondence Table
P
ar
a
me
te
r
Cop
y
P
ar
a
me
te
r
Cle
a
r
All P
ara
me
te
r
Cle
a
r
Re
ad
Wr
it
e
E
xt
ende
d
V/F
con
tr
o
l
Advanced
magnetic
flux
vector
control
Vector control
Real sensorless
vector control
S
p
eed
co
nt
ro
l
To
rque
co
nt
ro
l
Po
sit
ion
co
nt
ro
l
Speed
control
Torque
control
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...