166
166
PARAMETER
PARAMETER
PA
R
A
M
E
T
E
R
2
Cal
ibr
at
ion p
a
ramet
e
rs
C0
(900)
FM terminal calibration
—
—
—
C0
(900)
5C
DC
1
{
{
{
×
{
C1
(901)
AM terminal calibration
—
—
—
C1
(901)
5D
DD
1
{
{
{
×
{
C2
(902)
Terminal 2 frequency setting bias frequency 0 to 400Hz
0.01Hz
0Hz
C2
(902)
5E
DE
1
{
{
{
×
{
C3
(902)
Terminal 2 frequency setting bias
0 to 300%
0.1%
0%
C3
(902)
5E
DE
1
{
{
{
×
{
125
(903)
Terminal 2 frequency setting gain frequency 0 to 400Hz
0.01Hz
60Hz
125
(903)
5F
DF
1
{
{
{
×
{
C4
(903)
Terminal 2 frequency setting gain
0 to 300%
0.1%
100%
C4
(903)
5F
DF
1
{
{
{
×
{
C5
(904)
Terminal 4 frequency setting bias frequency 0 to 400Hz
0.01Hz
0Hz
C5
(904)
60
E0
1
{
{
{
×
{
C6
(904)
Terminal 4 frequency setting bias
0 to 300%
0.1%
20%
C6
(904)
60
E0
1
{
{
{
×
{
126
(905)
Terminal 4 frequency setting gain frequency 0 to 400Hz
0.01Hz
60Hz
126
(905)
61
E1
1
{
{
{
×
{
C7
(905)
Terminal 4 frequency setting gain
0 to 300%
0.1%
100%
C7
(905)
61
E1
1
{
{
{
×
{
—
989
Parameter copy alarm release
10, 100
1
10/100
—
989
59
D9
9
{
{
{
×
{
PU
990
PU buzzer control
0, 1
1
1
990
5A
DA
9
{
{
{
{
{
991
PU contrast adjustment
0 to 63
1
58
991
5B
DB
9
{
{
{
×
{
Cl
ea
r
pa
ra
met
e
rs
Pr.CL Parameter clear
0, 1
1
0
—
Pr.CL
—
FC
—
—
—
—
—
—
ALLC All parameter clear
0, 1
1
0
—
ALLC
—
FC
—
—
—
—
—
—
Er.CL Faults history clear
0, 1
1
0
—
Er.CL
—
F4
—
—
—
—
—
—
PCPY Parameter copy
0, 1, 2, 3
1
0
—
PCPY
—
—
—
—
—
—
—
—
*1
Differ according to capacities. (0.75K/1.5K to 3.7K/5.5K, 7.5K/11K to 37K/45K, 55K/75K or more)
*2
Differ according to capacities. (55K or less/75K or more)
*3
Differ according to capacities. (7.5K or less/11K or more)
*4
Differ according to capacities. (7.5K or less/11K to 55K/75K or more)
*5
Setting can be made for the 75K or more.
*6
The initial value differs according to the voltage class. (200V class/400V class)
*7
Can be read and written by only communication from the PU connector.
*8
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/FR-PU07).
*9
These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-
485 communication. (Refer to page 441 for RS-485 communication)
[Pr.]
Name
Setting Range
Minimum Setting
Increments
Initial value Reference
[Pr.]
Option
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Copy
Parameter
Clear
All Parameter
Clear
Read
Write Extended
V/F
control
Simple
magnetic
flux vector
control
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...