207
2
P
ARAM
ETE
R
PARAMETER
Function assignment
of external terminal
and control
Function assignment of input terminal
[
Pr. 178 to Pr. 184
]
[
Pr. 178 to Pr. 182
]
Start signal selection
[
Pr. 250
]
[
Pr. 250
]
Logic selection of output stop signal
(MRS)
[
Pr. 17
]
[
Pr. 17
]
Function assignment of output terminal
[
Pr. 190 to Pr. 192
]
[
Pr. 190
], [
Pr. 192
]
Detection of output frequency (SU, FU
signal)
[
Pr. 41 to Pr. 43
]
[
Pr. 41 to Pr. 43
]
Detection of output current (Y12 signal)
Detection of zero current (Y13 signal)
[
Pr. 150 to 153
]
[
Pr. 150 to 153
], [
Pr. 166
], [
Pr. 167
]
Remote output function (REM signal)
[
Pr. 495 to Pr. 497
]
[
Pr. 495
], [
Pr. 496
]
Monitor display and
monitor output signal
Speed display and speed setting
[
Pr. 37
]
[
Pr. 37
]
Change of DU/PU monitor descriptions
Cumulative monitor clear
[
Pr. 52
], [
Pr. 170
], [
Pr. 171
], [
Pr. 563
],
[
Pr. 564
]
[
Pr. 52
], [
Pr. 170
], [
Pr. 171
], [
Pr. 563
],
[
Pr. 564
], [
Pr. 891
]
Change of the monitor output from
terminal FM
[
Pr. 54 to Pr. 56
]
[
Pr. 54 to Pr. 56
]
Selection of the decimal digits of the
monitor
[
Pr. 268
]
[
Pr. 268
]
Adjustment of terminal FM output
(calibration)
[
C0
]([
Pr. 900
]) [
C0
]([
Pr. 900
])
Detection of output
frequency, current
Detection of output frequency (SU, FU
signal)
[
Pr. 41 to Pr. 43
]
[
Pr. 41 to Pr. 43
]
Detection of output current (Y12 signal)
Detection of zero current (Y13 signal)
[
Pr. 150
to
Pr. 153
]
[
Pr. 150 to Pr. 153
], [
Pr. 166
], [
Pr. 167
]
Operation selection
at power failure and
instantaneous power
failure
Automatic restart operation after
instantaneous power failure/flying start
[
Pr. 57
], [
Pr. 58
], [
Pr. 162
], [
Pr. 165
],
[
Pr. 298
], [
Pr. 299
], [
Pr. 611
]
[
Pr. 57
], [
Pr. 58
], [
Pr. 162
], [
Pr. 165
],
[
Pr. 298
], [
Pr. 299
], [
Pr. 611
]
When undervoltage or a power failure
occurs, the inverter can be decelerated
to a stop
[
Pr. 261
]
[
Pr. 261
]
Operation setting at
fault occurrence
Retry function at fault occurrence
[
Pr. 65
], [
Pr. 67 to Pr. 69
]
[
Pr. 65
], [
Pr. 67 to Pr. 69
]
Input/output phase loss protection
selection
[
Pr. 251
], [
Pr. 872
]
[
Pr. 251
], [
Pr. 872
]
Earth (ground) fault detection at start
[
Pr. 249
]
[
Pr. 249
]
Regeneration avoidance function
[
Pr. 665
], [
Pr. 882
], [
Pr. 883
], [
Pr. 885
],
[
Pr. 886
]
[
Pr. 665
], [
Pr. 882
], [
Pr. 883
], [
Pr. 885
],
[
Pr. 886
]
Energy saving
operation
Energy saving control selection
[
Pr. 60
]
[
Pr. 60
]
Reduction of the
motor noise
Measures against
EMI and leakage
currents
Carrier frequency and Soft-PWM
selection
[
Pr. 72
], [
Pr. 240
]
[
Pr. 72
], [
Pr. 240
], [
Pr. 260
]
Noise elimination at the analog input
[
Pr. 74
]
[
Pr. 74
]
Reduce mechanical resonance (speed
smoothing control)
[
Pr. 653
]
[
Pr. 653
]
Frequency setting by
analog input
Analog input selection
[
Pr. 73
], [
Pr. 267
]
[
Pr. 73
], [
Pr. 267
]
Noise elimination at the analog input
[
Pr. 74
]
[
Pr. 74
]
Change of analog input frequency,
Adjustment of voltage, current input and
frequency (calibration)
[
Pr. 125
], [
Pr. 126
], [
Pr. 241
], [
C2 to
C7
] ([
Pr. 902 to Pr. 905
])
[
Pr. 125
], [
Pr. 126
], [
Pr. 241
], [
C2 to
C7
] ([
Pr. 902 to 905
])
Purpose of Use
Parameter Number
FR-E700
FR-D700
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...