2.18.7 Setting from the parameter unit and operation panel [Pr. 40*, 145, 161, 295*, 990,
991]
(common)
Parameter unit (FR-PU04/FR-PU07), operation panel (FR-DU07) can be set.
(1) RUN key rotation direction selection
[Pr. 40]
Used to choose the direction of rotation by
operating
of the operation panel.
(2) PU display language selection [Pr.
145]
The display language of the parameter unit (FR-
PU04/FR-PU07) can be changed to other language
using [
Pr. 145
] .
(3) Operation panel frequency setting/key
lock operation selection [Pr. 161]
The setting dial of the operation panel (FR-DU07)
can be used like a potentiometer and key operation
of the operation panel can be invalid by setting [
Pr.
161
]. For details refer to page 214.
(4) Magnitude of frequency change setting
[Pr. 295]
When setting the set frequency with the setting dial,
frequency changes in 0.01Hz increments in the initial
status. Setting [
Pr. 295
] increases the magnitude of
frequency which changes according to the rotated
amount of the setting dial, improving usability.
For example, when "1.00Hz" is set in [
Pr. 295
], one
click (one dial gauge) of the setting dial changes the
frequency in increments of 1.00Hz
→
2.00Hz
→
3.00Hz.
Magnitude of frequency change works only for the
set frequency. Magnitude of frequency changes for
other parameters which are set in frequency is not
changed by
Pr. 295
.
When 10 is set, the setting changes in 10Hz
increments. Be cautious for the excess speed (in
potentiometer mode)
Minimum increment for the magnitude of change is
also determined by [
Pr. 295
] setting when machine
speed unit is displayed by [
Pr. 37
] setting. However,
setting value may differ since a set machine speed is
converted to frequency, then the frequency is
converted back to speed.
common
(*Not available for
.)
[Pr. ]
Name
Initial
Value
Setting
Range
Description
Available
Inverters
40
RUN key rotation direction
selection
0
0
Forward rotation
—
{
1
Reverse rotation
145
PU display language
selection
0
0
Japanese
{
{
1
English
2
German
3
French
4
Spanish
5
Italian
6
Swedish
7
Finnish
161
Frequency setting/key lock
operation selection
0
0
Setting dial frequency setting mode
Key lock invalid
{
{
1
Setting dial potentiometer mode
10
Setting dial frequency setting mode
Key lock valid
11
Setting dial potentiometer mode
295
Magnitude of frequency
change setting
0
0
Function invalid
—
{
0.01
The minimum varying width when the set frequency is
changed by the setting dial can be set.
0.10
1.00
10.00
990
*1
PU buzzer control
1
0
Without buzzer
{
{
1
With buzzer
991
*1*2
PU contrast adjustment
58
0 to 63
0: Light
↓
63: Dark
{
{
*1
The above parameter allow its setting to be changed during operation in any operation mode even if [
Pr. 77
Parameter write selection
= 0].
*2
This parameter is displayed as simple mode parameter only when the parameter unit (FR-PU04/FR-PU07)
is connected.
A700
F700
#
(
'
&
'
&
common
common
'
&
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...