54
4.2.9
Parameter copy and parameter verification
(1) Parameter copy
PCPY Setting
Description
0
Cancel
1
Copy the source parameters to the operation panel.
2
Write the parameters copied to the operation panel into the destination inverter.
3
Verify parameters in the inverter and operation panel.
(Refer to page 55.)
REMARKS
· When the copy destination inverter is not the FR-A701 series or parameter copy write is performed after parameter copy read is
stopped, "model error (
)" is displayed.
· Refer to the
parameter list on
page 98
and later for availability of parameter copy.
· When the power is turned off or an operation panel is disconnected, etc. during parameter copy write, perform write again or
check the values by parameter verification.
Parameter settings can be copied to multiple inverters.
1.
Connect the operation panel to the
copy source inverter.
•
Connect it during a stop.
Display
Operation
2.
Press to choose the parameter
setting mode.
Flicker ··· Parameter copy complete!!
6.
Press to copy the source parameters
to the operation panel.
4.
Press to to read the currently set value.
" "(initial value) appears.
Flicker ··· Parameter copy complete!!
9.
Press to write the parameters copied to
the operation panel to the destination inverter.
3.
Turn until (parameter copy)
appears.
5.
Turn to change it to the setting value
" ".
Flickers for about 30s
The frequency flickers
for about 30s
About 30s later
10.
When copy is completed,
" " and " " flicker.
11.
After writing the parameter values to the copy
destination inverter, always reset the inverter,
e.g. switch power off once, before starting operation.
7.
Connect the operation panel to the
copy source inverter.
8.
After performing steps 2 to 5,
turn to change it to " ".
The parameter
number previously
read appears.
Summary of Contents for FR-A741-11K
Page 7: ...MEMO ...
Page 216: ...209 MEMO ...