78
PPO TYPE NON-SUPPORT SPECIFICATION
8.8.2 Pr. 900 to calibration parameter (frequency) area (IND=0300H (IND=03H,
PP=00H))
The following parameters can be set with IND=0300H.
*1 These parameters can be set for the Japanese version only.
*2 This parameter can be set for the NA, EC and CH versions only.
IND
PNU
Parameter
Number
Name
Minimum
Setting
Increments
Setting Range
Decimal
Hexadecimal
0300H
0H
900
FM terminal calibration
-
-
-
0300H
1H
901
AM terminal calibration
-
-
-
0300H
2H
902
Terminal 2 frequency setting bias frequency
0.01Hz
0 to 400
0 to 9C40
0300H
3H
903
Terminal 2 frequency setting gain frequency
0.01Hz
0 to 400
0 to 9C40
0300H
4H
904
Terminal 4 frequency setting bias frequency
0.01Hz
0 to 400
0 to 9C40
0300H
5H
905
Terminal 4 frequency setting gain frequency
0.01Hz
0 to 400
0 to 9C40
0300H 16H
922
Frequency setting voltage bias frequency (built-
in potentiometer)
0.01Hz
0 to 400
0 to 9C40
0300H 17H
923
Frequency setting voltage gain frequency (built-
in potentiometer)
0.01Hz
0 to 400
0 to 9C40