54
PPO TYPE SUPPORT SPECIFICATION
7.7.2 Parameter clear
Parameter clear can be performed from the master.
* Communication parameters
(Pr. 117 to Pr. 124, Pr. 338 to Pr. 340, Pr. 343, Pr. 349, Pr. 549 to Pr. 551)
are not cleared.
Turning OFF the power supply while clearing parameters with 5A96H or AA99H also clears the communication parameter settings back to the
initial settings.
7.7.3 Operation mode read/write
Read/write of the operation mode can be performed from the master.
7.7.4 Set frequency read
The frequency set to the inverter can be read from the master.
* It is always displayed as frequency (Hz) regardless of the
Pr. 37
setting.
PNU
Item
Data Definition
Data Type
P2.2
Parameter clear
965AH
AUs16
P2.3
All parameter clear
99AAH
AUs16
P2.5
Parameter clear*
5A96H
AUs16
P2.6
All parameter clear*
AA99H
AUs16
P2.8
Faults history clear
0000H
AUs16
PNU
Item
Data Definition
Data Type
P3
Operation mode read/write
External operation mode:10H
PU operation mode:11H (
Pr.79
= "6")
Network operation mode:14H
Us16
PNU
Item
Data Definition
Data Type
P4.1
Set frequency (RAM) read*
Set frequency (RAM) is read.
AUs16
P4.2
Set frequency (EEPROM) read*
Set frequency (EEPROM) is read.
AUs16