5 BASIC OPERATION
5.1 Operation panel (FR-DU08)
5.1.1 Components of the operation panel (FR-DU08)
To mount the operation panel (FR-DU08) on the enclosure surface, refer to the "FR-A800 Instruction Manual (Detailed)".
No.
Component
Name
Description
A
Inverter operation
mode LED indicator
PU:
Lit to indicate the PU operation mode.
EXT:
Lit to indicate the External operation mode.
(Lit at power-ON in the initial setting.)
NET:
Lit to indicate the Network operation mode.
PU and EXT: Lit to indicate the External/PU combined operation mode 1 or 2.
B
Operation panel mode
LED indicator
MON: Lit to indicate the monitoring mode.
Quickly flickers twice intermittently while the protective function is
activated. Slowly flickers in the display-OFF mode.
PRM: Lit to indicate the parameter setting mode.
C
Controlled motor type
LED indicator
IM:
Always lit while the inverter power is ON. The indicator flickers when the vector
control test operation is selected. (The indicators may go OFF during an
inverter reset or in some other cases.)
PM:
Not used.
D
Frequency unit LED
indicator
Lit to indicate the actual frequency.
(Flickers when the set frequency is displayed in the monitor.)
E
Monitor (5-digit LED)
Shows a numeric value (readout) of a monitor item such as the frequency, a parameter
number, etc.
(Using Pr. 52, Pr. 774 to Pr. 776, the monitored item can be changed.)
F
PLC function LED
indicator
Lit to indicate that the PLC function of the inverter is valid.
G
FWD key, REV key
FWD key: Starts forward rotation. The LED is lit during forward operation.
REV key:
Starts reverse rotation. The LED is lit during reverse operation.
Either LED flickers under the following conditions.
O
When the frequency command is not given even if the forward/reverse command is
given.
O
When the frequency command is the starting frequency or lower.
O
When the MRS signal is being input.
H
STOP/RESET key
Stops the operation commands.
Resets the inverter when the protection function is activated.
I
Setting dial
The setting dial of the Mitsubishi Electric inverters. Turn the setting dial to change the
setting of frequency or parameter etc.
Press the setting dial to perform the following operations:
O
To display a set frequency on the LED display in the monitoring mode
(the monitor item shown on the display can be changed using Pr. 992.)
O
To display the present setting during calibration
O
To display a fault history number on the LED display in the faults history mode.
J
MODE key
Switches the operation panel to a different mode.
Pressing the "MODE" and "PU/EXT keys simultaneously switches to the easy setting
mode.
Every key on the operation panel becomes inoperable by holding this key for 2
seconds. The key lock is invalid when Pr. 161 = "0 (initial setting)". (Refer to the FR-A800
Instruction Manual (Detailed).)
K
SET key
Confirms each setting.
Switches the monitor screen in the monitor
mode.
(Using Pr. 52 and Pr. 774–Pr. 776, the
monitored item on each screen can be
changed.)
L
ESC key
Goes back to the previous display.
Holding this key for a longer time changes the mode back to the monitor mode.
M
PU/EXT key
Switches between the PU operation mode, the PU JOG operation mode and the
External operation mode.
Pressing the "MODE" and "PU/EXT" keys simultaneously switches to the easy setting
mode.
Also cancels the PU stop warning.
A
B
C
D
E
F
G
H
I
J
K
L
M
Output
frequency
Output
current
Output
voltage
Initial setting in the monitor mode