33
BASIC OPERATION
243
Terminal 1 added
compensation amount
(terminal 4)
0 to 100%
75%
244
Cooling fan operation
selection
0, 1, 101 to 105
1
245
Rated slip
0 to 50%, 9999
9999
246
Slip compensation
time constant
0.01 to 10 s
0.5 s
247
Constant-power range
slip compensation
selection
0, 9999
9999
249
Earth (ground) fault
detection at start
0, 1
0
250
Stop selection
0 to 100 s,
1000 to 1100 s,
8888, 9999
9999
251
Output phase loss
protection selection
0, 1
1
252
Override bias
0 to 1000%
50%
253
Override gain
0 to 1000%
150%
255
Life alarm status
display
(0 to 15)
0
256
*14 Inrush current limit
circuit life display
(0 to 100%)
100%
257
Control circuit
capacitor life display
(0 to 100%)
100%
258
*14 Main circuit capacitor
life display
(0 to 100%)
100%
259
*14 Main circuit capacitor
life measuring
0, 1
0
260
PWM frequency
automatic switchover 0, 1
1
261
Power failure stop
selection
0 to 2, 11, 12, 21,
22
0
262
Subtracted frequency
at deceleration start
0 to 20 Hz
3 Hz
263
Subtraction starting
frequency
0 to 590 Hz, 9999 60/50 Hz
*10
264
Power-failure
deceleration time 1
0 to 3600 s
5 s
265
Power-failure
deceleration time 2
0 to 3600 s,
9999
9999
266
Power failure decelera
-
tion time switchover
frequency
0 to 590 Hz
60/50 Hz
*10
267
Terminal 4 input
selection
0 to 2
0
268
Monitor decimal digits
selection
0, 1, 9999
9999
269
Parameter for manufacturer setting. Do not set.
270
Acceleration/
deceleration time
during stall condition
0 to 3600 s
15 s
271
Second acceleration
time for inertia
compensation
0 to 3600 s
15 s
272
Second deceleration
time for inertia
compensation
0 to 3600 s
15 s
Parameter Name
Setting range
Initial value
276
Line speed monitoring
reference
0 to 6553.4 m/
min
*11
1000 m/min
*11
278
Actual line speed
voltage/current gain
0 to 100%, 9999
9999
279
Actual line speed gain 0 to 6553.4 m/
min
*11
, 9999
9999
280
Actual line speed
voltage/current bias
0 to 100%, 9999
9999
281
Actual line speed bias 0 to 6553.4 m/
min
*11
, 9999
9999
282
Actual line speed
pulse input bias
0 to 500, 9999
9999
283
Actual line speed
pulse input gain
0 to 500, 9999
9999
284
Actual line speed
input filter time
constant
0 to 5 s
0.02 s
285
Overspeed detection
frequency (Excessive
speed deviation
detection frequency)
0 to 30 Hz, 9999
9999
286
Droop gain
0 to 100%
0%
287
Droop filter time
constant
0 to 1 s
0.3 s
288
Droop function
activation selection
0 to 2, 10, 11,
20 to 22
0
289
Inverter output
terminal filter
5 to 50 ms, 9999
9999
290
Monitor negative
output selection
0 to 7
0
291
Pulse train I/O
selection
0, 1, 10, 11, 20, 21,
100
(FM type)
0
0, 1 (CA type)
294
UV avoidance voltage
gain
0 to 200%
100%
295
Frequency change
increment amount
setting
0, 0.01, 0.10, 1.00,
10.00
0
296
Password lock level
0 to 6, 99, 100 to
106, 199, 9999
9999
297
Password lock/unlock
(0 to 5),
1000 to 9998,
9999
9999
298
Frequency search gain 0 to 32767, 9999
9999
299
Rotation direction
detection selection at
restarting
0, 1, 9999
0
313
DO0 output selection 0 to 8, 10 to 16,
25, 26, 30 to 35,
39 to 48, 55, 64,
68, 79, 80, 85 to
99, 100 to 108,
110 to 116, 125,
126, 130 to 135,
139 to 148, 155,
164, 168, 179,
180, 185 to 199,
206 to 208,
211 to 213,
231 to 239, 242,
306 to 308,
311 to 313,
331 to 339, 342,
9999
*18
9999
314
DO1 output selection
9999
315
DO2 output selection
9999
316
DO3 output selection
9999
317
DO4 output selection
9999
318
DO5 output selection
9999
319
DO6 output selection
9999
Parameter Name
Setting range
Initial value
*10
Differs according to types. (FM type/CA type)
*11
The increment varies depending on the Pr. 358 setting.
*14
The setting range or initial value is for standard models.
*18
The setting values "242" and "342" are available for the Ethernet models only.