37
BASIC OPERATION
606
Power failure stop
external signal input
selection
0, 1
1
607
Motor permissible load
level
110 to 250%
150%
608
Second motor
permissible load level
110 to 250%,
9999
9999
611
Acceleration time at a
restart
0 to 3600 s,
9999
9999
617
Reverse rotation
excitation current low-
speed scaling factor
0 to 300%, 9999
9999
620
Line speed bias for reel
change
0 to 2000 m/min
*11
1000 m/min
*11
621
Allowable deviation
from target line speed
0 to 6553.4 m/
min
*11
0 m/min
*11
622
Line speed command
for starting
0 to 6553.4 m/
min
*11
0 m/min
*11
635
Line speed command
added compensation
value voltage/current
bias
0 to 100%, 9999
9999
636
Line speed command
added compensation
value bias
0 to 6553.4 m/
min
*11
, 9999
9999
637
Line speed command
added compensation
value voltage/current
gain
0 to 100%, 9999
9999
638
Line speed command
added compensation
value gain
0 to 6553.4 m/
min
*11
, 9999
9999
639
Speed control
proportional term
applied diameter 1
1 to 99%, 9999
9999
640
Speed control
proportional term
applied diameter 2
1 to 99%, 9999
9999
641
Speed control
proportional gain 1
0 to 1000%, 9999
9999
642
Speed control
proportional gain 2
0 to 1000%, 9999
9999
643
Speed control
proportional gain 3
0 to 1000%, 9999
9999
644
Speed control
proportional gain 4
0 to 1000%, 9999
9999
645
Winding diameter
storage selection
0, 1
0
646
Stored winding
diameter
1 to 6553 mm
1 mm
647
Operation time with
stored winding
diameter
0 to 100 s
0 s
648
Target winding
diameter
1 to 6553 mm
1 mm
650
Terminal 4 input
compensation
selection
0, 1
0
653
Speed smoothing
control
0 to 200%
0%
654
Speed smoothing
cutoff frequency
0 to 120 Hz
20 Hz
655
Analog remote output
selection
0, 1, 10, 11
0
Parameter Name
Setting range
Initial value
656
Analog remote output
1
800 to 1200%
1000%
657
Analog remote output
2
800 to 1200%
1000%
658
Analog remote output
3
800 to 1200%
1000%
659
Analog remote output
4
800 to 1200%
1000%
663
Control circuit
temperature signal
output level
0 to 100 °C
0 °C
665
Regeneration
avoidance frequency
gain
0 to 200%
100%
668
Power failure stop
frequency gain
0 to 200%
100%
673
SF-PR slip amount
adjustment operation
selection
2, 4, 6, 9999
9999
674
SF-PR slip amount
adjustment gain
0 to 500%
100%
675
User parameter auto
storage function
selection
1, 9999
9999
679
Second droop gain
0 to 100%, 9999
9999
680
Second droop filter
time constant
0 to 1 s, 9999
9999
681
Second droop function
activation selection
0 to 2, 10, 11, 20
to 22, 9999
9999
682
Second droop break
point gain
0.1 to 100%,
9999
9999
683
Second droop break
point torque
0.1 to 100%,
9999
9999
684
Tuning data unit
switchover
0, 1
0
686
Maintenance timer 2
0 (1 to 9998)
0
687
Maintenance timer 2
warning output set
time
0 to 9998, 9999
9999
688
Maintenance timer 3
0 (1 to 9998)
0
689
Maintenance timer 3
warning output set
time
0 to 9998, 9999
9999
690
Deceleration check
time
0 to 3600 s, 9999
1 s
692
Second free thermal
reduction frequency 1 0 to 590 Hz, 9999
9999
693
Second free thermal
reduction ratio 1
1 to 100%
100%
694
Second free thermal
reduction frequency 2
0 to 590 Hz, 9999
9999
695
Second free thermal
reduction ratio 2
1 to 100%
100%
696
Second free thermal
reduction frequency 3
0 to 590 Hz, 9999
9999
699
Input terminal filter
5 to 50 ms, 9999
9999
707
Motor inertia (integer) 10 to 999, 9999
9999
724
Motor inertia
(exponent)
0 to 7, 9999
9999
744
Second motor inertia
(integer)
10 to 999, 9999
9999
745
Second motor inertia
(exponent)
0 to 7, 9999
9999
Parameter Name
Setting range
Initial value
*11
The increment varies depending on the Pr. 358 setting.