Restrictions and precautions for parameter setting
17
5.2
Restrictions and precautions for parameter setting
For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the necessary parameters to meet the load
and operational specifications. Parameter setting, change and check can be performed from the operation panel (FR-DU08).
NOTE
• For the parameters not found in this Instruction Manual, refer to the Instruction Manual (Detailed) of the FR-A800 inverter.
• The initial values of the following parameters in the FR-B or FR-B3 inverter are different from those in the FR-A800 inverter because the values change
depending on the applied motor.
• Settings of the following parameters are restricted to satisfy the explosion-proof specifications. Always use the parameters under restrictions.
The following regeneration unit can be used.
Inverter capacity
Regeneration unit
22K or lower
FR-ABR, FR-BU2
30 to 55K
FR-BU2
75K or higher
FR-BU2, FR-HC2
FR-B
FR-B3
Pr.
Name
Initial value
0
Torque boost
7.5K or lower, 200 V class 75K, 400 V
class 90K or higher: 2%
11K to 55K: 1.5%
400 V class 75K: 1%
1
Maximum frequency
60 Hz
10
DC injection brake operation frequency 55K or lower: 3 Hz
75K or higher: 1 Hz
11
DC injection brake operation time
55K or lower: 0.5 s
75K or higher: 0 s
18
High speed maximum frequency
60 Hz
72
PWM frequency selection
200 V class 55K or lower, 400 V class: 1
200 V class 75K: 2
100
V/F1 (first frequency)
55K or lower: 6 Hz
75K or higher: 50 Hz
101
V/F1 (first frequency voltage)
200 V class 55K or lower: 30 V
400 V class 55K or lower: 60 V
200 V class 75K: 200 V
400 V class 75K or higher: 400 V
102
V/F2 (second frequency)
55K or lower: 50 Hz
75K or higher: 9999
103
V/F2 (second frequency voltage)
200 V class 55K or lower: 200 V
400 V class 55K or lower: 400 V
75K or higher: 0
240
Soft-PWM operation selection
0
1121
Per-unit speed control reference
frequency
60 Hz
Pr.
Name
Initial value
71
Applied motor
13
72
PWM frequency selection
FR-B3: 2
FR-B3-N: 15
80
Motor capacity
Inverter rated capacity
81
Number of motor poles
4
Pr.
Name
Initial value
Pr.
Name
FR-B
FR-B3
0
Torque boost
1
Maximum frequency
The setting must be within
the following range.
22K or lower: 0 to 120 Hz
30K or higher: 0 to 60 Hz
3
Base frequency
10
DC injection brake
operation frequency
11
DC injection brake
operation time
12
DC injection brake
operation voltage
18
High speed maximum
frequency
19
Base frequency voltage
30
Regenerative function
selection
The setting must be within
the following range.
55K or lower: 0, 1, 100, 101
75K or higher: 0, 1, 2, 100,
101, 102
The setting must be within
the following range.
0, 1, 100, 101
46
Second torque boost
60
Energy saving control
selection
71
Applied motor
The setting must be within
the following range.
0, 1
72
PWM frequency
selection
The setting must be within
the following range.
55K or lower: 1 to 15
200 V class 75K: 2
400 V class 75K or higher: 1,
2
75
Reset selection/
disconnected PU
detection/PU stop
selection
The setting must be within
the following range.
55K or lower:
0 to 3, 14 to 17,
1000 to 1003, 1014 to 1017
75K or higher:
0 to 3, 14 to 17, 100 to 103,
114 to 117, 1000 to 1003,
1014 to 1017, 1100 to 1103,
1114 to 1117
The setting must be within
the following range.
0 to 3, 14 to 17,
1000 to 1003, 1014 to 1017
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
85
Excitation current
refraction point
86
Excitation current low-
speed multiplying factor
89
Speed control gain
(Advanced magnetic flux
vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)/d-
axis inductance (Ld)
93
Motor constant (L2)/q-
axis inductance (Lq)
94
Motor constant (X)
95
Online auto tuning
selection
100 V/F1 (first frequency)
101 V/F1 (first frequency
voltage)
102 V/F2 (second frequency)
103 V/F2 (second frequency
voltage)
104 V/F3 (third frequency)
105 V/F3 (third frequency
voltage)
106 V/F4 (fourth frequency)
107 V/F4 (fourth frequency
voltage)
108 V/F5 (fifth frequency)
109 V/F5 (fifth frequency
voltage)
112 Third torque boost
135 Electronic bypass
sequence selection
178
to
189
(Input terminal function
selection)
Do not set "18" (V/F
switchover).
240 Soft-PWM operation
selection
245 Rated slip
260 PWM frequency
automatic switchover
276 PWM carrier frequency
at stop-on contact
292 Automatic acceleration/
deceleration
450 Second applied motor
451 Second motor control
method selection
570 Multiple rating setting
Non-existent parameter
Non-existent parameter
598 Undervoltage level
The setting must be within
the following range.
200 V class 45K or lower:
175 to 215 VDC
617
Reverse rotation
excitation current low-
speed scaling factor
660
Increased magnetic
excitation deceleration
operation selection
673
SF-PR slip amount
adjustment operation
selection
800 Control method selection
859 Torque current/Rated PM
motor current
998 PM parameter
initialization
999 Automatic parameter
setting
: No restriction on setting,
: Setting change not allowed
Pr.
Name
FR-B
FR-B3