128
Monitor display and monitor output signal
4.11.3 Reference of the terminal AM (analog voltage output) (Pr. 55, Pr. 56)
Analog voltage output from the terminal AM is available.
Set the reference of the signal output from terminal AM.
Parameter
Number
Name
Initial Value
Setting Range
Description
55*
Frequency monitoring
reference
50Hz
0 to 400Hz
Full-scale value to output the output frequency
monitor value to terminal AM.
56*
Current monitoring
reference
Inverter
rated current
0 to 500A
Full-scale value to output the output current
monitor value to terminal AM.
The above parameters can be set when
Pr. 160 Extended function display selection
=
"
0
"
.
* The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in
Pr. 77 Parameter write selection
.
(1) Frequency monitoring reference (
Pr. 55
)
• Set the frequency when the optional frequency meter (DC voltmeter
10VDC) shows 50Hz or 120Hz (shows full scale) which is connected
to the terminal AM and 5.
• Set the frequency (output frequency/set frequency) when the voltage
output at terminal AM is 10VDC.
• The analog voltage output and frequency at terminal AM are
proportional. (The maximum output voltage is 10VDC.)
(2) Current monitoring reference (
Pr. 56
)
• Set the current to be referenced when the current monitor (inverter
output current, etc.) is selected for terminal AM display.
• Set the current value when the voltage output at terminal AM is
10VDC.
• The analog voltage output and current value at terminal AM are
proportional. (The maximum output voltage is 10VDC.)
Setting range of
Pr. 55
1Hz
400Hz
50Hz
(initial value)
Output voltage
10VDC
Setting range of
Pr. 56
Rated current
(initial value)
500A
T
erminal AM
output voltage
(10VDC)
Summary of Contents for FR-D700 Series
Page 11: ...VII MEMO ...
Page 23: ...12 MEMO ...
Page 57: ...46 MEMO ...
Page 262: ...258 MEMO ...
Page 276: ...272 MEMO ...
Page 287: ...283 MEMO ...
Page 289: ......