Parameter list
Parameter list
60
Parameter List
Life diag
nosis
255
Life alarm status display
(0 to 15)
1
0
255
3F
BF
2
×
×
×
256
Inrush current limit circuit life display
(0 to 100%)
1%
100%
256
40
C0
2
×
×
×
257
Control circuit capacitor life display
(0 to 100%)
1%
100%
257
41
C1
2
×
×
×
258
Main circuit capacitor life display
(0 to 100%)
1%
100%
258
42
C2
2
×
×
×
259
Main circuit capacitor life measuring
0, 1 (2, 3, 8, 9)
1
0
259
43
C3
2
—
260
PWM frequency automatic switchover
0, 1
1
0
260
44
C4
2
Power fail
u
re
stop
261
Power failure stop selection
0, 1, 2
1
0
261
45
C5
2
—
267
Terminal 4 input selection
0, 1, 2
1
0
267
4B
CB
2
×
—
268
Monitor decimal digits selection
0, 1, 9999
1
9999
268
4C
CC
2
—
269
Parameter for manufacturer setting. Do not set.
269
Parameter for manufacturer setting. Do not set.
—
295
Magnitude of frequency change setting
0, 0.01, 0.10, 1.00,
10.00
0.01
0
295
67
E7
2
Pa
ss
wo
rd
function
296
Password lock level
1 to 6, 101 to 106, 9999
1
9999
296
68
E8
2
×
297
Password lock/unlock
1000 to 9999 (0 to 5,
9999)
1
9999
297
69
E9
2
×
—
298
Frequency search gain
0 to 32767, 9999
1
9999
298
6A
EA
2
×
—
299
Rotation direction detection selection
at restarting
0, 1, 9999
1
0
299
6B
EB
2
RS-485 communication
338
Communication operation command
source
0, 1
1
0
338
26
A6
3
∗7
∗7
339
Communication speed command
source
0, 1, 2
1
0
339
27
A7
3
∗7
∗7
340
Communication startup mode selection 0, 1, 10
1
0
340
28
A8
3
∗7
∗7
342
Communication EEPROM write
selection
0, 1
1
0
342
2A
AA
3
343
Communication error count
—
1
0
343
2B
AB
3
×
×
×
S
e
cond moto
r
const
ant
450
Second applied motor
0, 1, 9999
1
9999
450
32
B2
4
Remote
Output
495
Remote output selection
0, 1, 10, 11
1
0
495
5F
DF
4
496
Remote output data 1
0 to 4095
1
0
496
60
E0
4
×
×
×
—
502
Stop mode selection at communication
error
0, 1, 2
1
0
502
02
82
5
Maintenance
503
Maintenance timer
0 (1 to 9998)
1
0
503
03
83
5
×
×
×
504
Maintenance timer alarm output set
time
0 to 9998, 9999
1
9999
504
04
84
5
×
C
ommunication
549
Protocol selection
0, 1
1
0
549
31
B1
5
∗7
∗7
551
PU mode operation command source
selection
2, 4, 9999
1
9999
551
33
B3
5
∗7
∗7
C
urren
t aver
age
time monitor
555
Current average time
0.1 to 1s
0.1s
1s
555
37
B7
5
556
Data output mask time
0 to 20s
0.1s
0s
556
38
B8
5
557
Current average value monitor signal
output reference current
0 to 500A
0.01A
Rated
inverter
current
557
39
B9
5
—
561
PTC thermistor protection level
0.5 to 30k
Ω
, 9999
0.01
Ω
9999
561
3D
BD
5
×
—
563
Energization time carrying-over times
(0 to 65535)
1
0
563
3F
BF
5
×
×
×
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Read
Write
Extended
Copy
Clear
All clear
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
Summary of Contents for FR-D700 Series
Page 11: ...VII MEMO ...
Page 23: ...12 MEMO ...
Page 57: ...46 MEMO ...
Page 262: ...258 MEMO ...
Page 276: ...272 MEMO ...
Page 287: ...283 MEMO ...
Page 289: ......