Parameter list
Parameter list
52
Parameter List
4.2 Parameter list
4.2.1
Parameter list
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made
from the operation panel. For details of parameters, refer to the instruction manual.
These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(
for RS-485 communication)
" " indicates valid and "
×
" indicates invalid of "control mode-based correspondence table", "parameter copy", "parameter clear", and "all parameter clear".
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Read
Write
Extended
Copy
Clear
All clear
Basic functions
0
Torque boost
0 to 30%
0.1%
6/4/3%
∗1
0
00
80
0
×
1
Maximum frequency
0 to 120Hz
0.01Hz
120Hz
1
01
81
0
2
Minimum frequency
0 to 120Hz
0.01Hz
0Hz
2
02
82
0
3
Base frequency
0 to 400Hz
0.01Hz
50Hz
3
03
83
0
×
4
Multi-speed setting (high speed)
0 to 400Hz
0.01Hz
50Hz
4
04
84
0
5
Multi-speed setting (middle speed)
0 to 400Hz
0.01Hz
30Hz
5
05
85
0
6
Multi-speed setting (low speed)
0 to 400Hz
0.01Hz
10Hz
6
06
86
0
7
Acceleration time
0 to 3600s
0.1s
5/10s
∗2
7
07
87
0
8
Deceleration time
0 to 3600s
0.1s
5/10s
∗2
8
08
88
0
9
Electronic thermal O/L relay
0 to 500A
0.01A
Rated
inverter
current
9
09
89
0
D
C
inj
ec
tio
n
bra
ke
10
DC injection brake operation frequency 0 to 120Hz
0.01Hz
3Hz
10
0A
8A
0
11
DC injection brake operation time
0 to 10s
0.1s
0.5s
11
0B
8B
0
12
DC injection brake operation voltage
0 to 30%
0.1%
6/4%
∗3
12
0C
8C
0
—
13
Starting frequency
0 to 60Hz
0.01Hz
0.5Hz
13
0D
8D
0
—
14
Load pattern selection
0 to 3
1
0
14
0E
8E
0
×
JO
G
opera
tion
15
Jog frequency
0 to 400Hz
0.01Hz
5Hz
15
0F
8F
0
16
Jog acceleration/deceleration time
0 to 3600s
0.1s
0.5s
16
10
90
0
—
17
MRS input selection
0, 2, 4
1
0
17
11
91
0
—
18
High speed maximum frequency
120 to 400Hz
0.01Hz
120Hz
18
12
92
0
—
19
Base frequency voltage
0 to 1000V, 8888, 9999
0.1V
8888
19
13
93
0
×
Accel
erati
on/
deceleration time
20
Acceleration/deceleration reference
frequency
1 to 400Hz
0.01Hz
50Hz
20
14
94
0
St
al
l
pr
evention
22
Stall prevention operation level
0 to 200%
0.1%
150%
22
16
96
0
23
Stall prevention operation level
compensation factor at double speed
0 to 200%, 9999
0.1%
9999
23
17
97
0
Multi-
sp
eed
setting
24
Multi-speed setting (speed 4)
0 to 400Hz, 9999
0.01Hz
9999
24
18
98
0
25
Multi-speed setting (speed 5)
0 to 400Hz, 9999
0.01Hz
9999
25
19
99
0
26
Multi-speed setting (speed 6)
0 to 400Hz, 9999
0.01Hz
9999
26
1A
9A
0
27
Multi-speed setting (speed 7)
0 to 400Hz, 9999
0.01Hz
9999
27
1B
9B
0
—
29
Acceleration/deceleration pattern
selection
0, 1, 2
1
0
29
1D
9D
0
REMARKS
indicates simple mode parameters.
The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in
Pr. 77 Parameter write selection
.
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
Summary of Contents for FR-D700 Series
Page 11: ...VII MEMO ...
Page 23: ...12 MEMO ...
Page 57: ...46 MEMO ...
Page 262: ...258 MEMO ...
Page 276: ...272 MEMO ...
Page 287: ...283 MEMO ...
Page 289: ......