172
Selection of operation mode and operation location
4.16.2 Setting the speed by the operation panel
POINT
Use the operation panel to give a start command and a speed command. (PU operation)
Operation
example
Operate at 900r/min.
Operation Display
1.
Screen at power-ON
The monitor display appears.
2.
Change the
Pr. 79
setting to "1".
PU indicator is lit.
3.
Turn
to show the speed you want to set.
The speed blinks for about 5s.
4.
While the value is blinking, press
to set
the speed.
(If
is not pressed, the indication of the
value goes back to "
" (0r/min) after about 5s
of blinking. In that case, go back to "operation
step 3" and set the speed again.)
After about 3s of blinking, the indication of the
value goes back to "
" (monitor display).
Blink...speed setting complete!!
The monitor display appears after 3s.
5.
Start
acceleration
constant speed
Press
to start operation.
The speed value on the indication increases in
Pr. 7 Acceleration time,
and "
" (900r/min)
appears.
6.
To change the set speed, perform the operation in above steps 3 and 4. (Starting from the previously set speed.)
7.
Deceleration
stop
Press
to stop.
The speed value on the indication decreases in
Pr. 8 Deceleration time,
and the motor stops
rotating with "
" (0r/min) displayed.
Operation panel
Blinks for about 5s
Stop
Summary of Contents for FR-D720-0.2K-G
Page 45: ...34 MEMO ...
Page 293: ...290 MEMO ...