200
Communication operation and setting
Example) When reading the
C3 (Pr. 902)
and
C6 (Pr. 904)
settings from the drive unit of station 0
To read/write
C3 (Pr. 902)
and
C6
(Pr. 904)
after drive unit reset or parameter clear, execute from 1) again.
List of calibration parameters
[Special monitor selection No.]
Refer to
for details of the monitor description.
The data format is 6 digits (E2) when the following conditions are met:
Pr. 37
= "0.01 to 9998,"
Pr. 144
= "2 to 10," and the instruction code HFF = "01."
(
for
Pr. 37
and
Pr. 144
.)
Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, —: undetermined value)
The monitored values are retained even if a drive unit fault occurs. Resetting will clear the retained values.
REMARKS
Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an drive unit reset or
all clear is performed.
Computer Send Data
Drive Unit Send Data
Description
1)
ENQ 00 FF 0 01 7D
ACK 00
Set "H01" to the expansion link parameter.
2)
ENQ 00 EC 0 01 79
ACK 00
Set "H01" to second parameter changing.
3)
ENQ 00 5E 0 0A
STX 00 0000 ETX 20
C3 (Pr. 902)
is read. 0% is read.
4)
ENQ 00 60 0 F6
STX 00 0000 ETX 20
C6 (Pr. 904)
is read. 0% is read.
b15
b0
—
—
—
—
—
—
—
—
—
RH
RM
RL
—
—
STR
STF
b15
b0
—
—
—
—
—
—
—
—
—
—
ABC
—
—
—
—
RUN
Parameter
Name
Instruction
Code
Rea
d
Wr
ite
Ext
ended
C2 (902) Terminal 2 speed setting bias speed
5E DE
1
C3 (902) Terminal 2 speed setting bias
5E DE
1
125 (903) Terminal 2 speed setting gain speed
5F DF
1
C4 (903) Terminal 2 speed setting gain
5F DF
1
C5 (904) Terminal 4 speed setting bias speed
60
E0
1
C6 (904) Terminal 4 speed setting bias
60
E0
1
126 (905) Terminal 4 speed setting gain speed
61
E1
1
C7 (905) Terminal 4 speed setting gain
61
E1
1
C42 (934) PID display bias coefficient
22
A2
9
C43 (934) PID display bias analog value
22
A2
9
C44 (935) PID display gain coefficient
23
A3
9
C45 (935) PID display gain analog value
23
A3
9
Parameter
Name
Instruction
Code
Rea
d
Wr
ite
Ext
ended
Data
Description
Unit
H01
Rotation speed/Output frequency/
Machine speed
1/0.01Hz/
0.001
H02
Output current
0.01A
H03
Output voltage
0.1V
H05
Rotation speed setting/Frequency
setting/Machine speed
1/0.01Hz/
0.001
H08
Converter output voltage
0.1V
H09
Regenerative brake duty
0.1%
H0A
Electronic thermal relay function
load factor
0.1%
H0B
Output current peak value
0.01A
H0C
Converter output voltage peak value
0.1V
H0E
Output power
0.01kW
H0F
Input terminal status
—
H10
Output terminal status
—
H14
Cumulative energization time
1h
H17
Actual operation time
1h
H18
Motor load factor
0.1%
H19
Cumulative power
1kWh
H34
PID set point
0.1%
H35
PID measured value
0.1%
H36
PID deviation
0.1%
H3D
Motor thermal load factor
0.1%
H3E
Drive unit thermal load factor
0.1%
H3F
Cumulative power 2
0.01kWh
H40
PTC thermistor resistance
0.01k
H4D
32-bit cumulative power
(lower 16-bit)
1kWh
H4E
32-bit cumulative power
(upper 16-bit)
1kWh
H4F
32-bit cumulative power
(lower 16-bit)
0.01kWh
H50
32-bit cumulative power
(upper 16-bit)
0.01kWh
Data