284
Rating
7.1 Rating
Three-phase 200V power supply
Three-phase 400V power supply
The rated output capacity assumes the following output voltages: 230V for three-phase 200V, and 440V for three-phase 400V.
The power supply capacity varies with the value of the power supply side drive unit impedance (including those of the input reactor and cables).
Model FR-D720-
K-G
0.2
0.4
0.75
1.5
2.2
3.7
Out
put
Rated capacity (kVA)
0.3
0.6
1.0
1.7
2.8
4.0
Rated current (A)
1.4
2.5
4.2
7.0
10.0
16.5
Overload current rating
150% 60s, 200% 0.5s (Rated motor current, inverse-time characteristics)
Pow
er supply
Rated input AC voltage/frequency
Three-phase 200 to 240V 50Hz/60Hz
Permissible AC voltage fluctuation
170 to 264V 50Hz/60Hz
Permissible frequency fluctuation
±5%
Power supply capacity (kVA)
0.4
0.7
1.2
2.1
4.0
5.5
Protective structure (JEM1030)
Enclosed type (IP20)
Cooling system
Self-cooling
Forced air cooling
Approximate mass (kg)
0.5
0.8
1.0
1.4
1.4
1.8
Model FR-D740-
K-G
0.4
0.75
1.5
2.2
3.7
Output
Rated capacity (kVA)
0.4
0.9
1.7
2.7
3.8
Rated current (A)
1.2
2.2
3.6
5.0
8.0
Overload current rating
150% 60s, 200% 0.5s (Rated motor current, inverse-time characteristics)
Power s
up
pl
y
Rated input AC voltage/frequency
Three-phase 380 to 480V 50Hz/60Hz
Permissible AC voltage fluctuation
325 to 528V 50Hz/60Hz
Permissible frequency fluctuation
±5%
Power supply capacity (kVA)
0.9
1.5
2.5
5.5
9.5
Protective structure (JEM1030)
Enclosed type (IP20)
Cooling system
Natural
Forced air
Approximate mass (kg)
1.3
1.3
1.4
1.5
1.5
Summary of Contents for FR-D720-0.2K-G