52
4.1.3
Easy operation mode setting (easy setting mode)
Setting of
Pr. 79 Operation mode selection
according to combination of the start command and speed command can be
easily made.
Changing
example
Start command: external (STF/STR), speed command: operate with
Operation Display
1.
Screen at power-ON
The monitor display appears.
2.
Easy operation mode setting
Press and for
0.5s.
3.
Operation mode selection
Turn
until "
" appears.
(Refer to the table below for other settings.)
4.
Operation mode setting
Press
to set.
Blink ··· Parameter setting complete!!
The monitor display appears after 3s.
REMARKS
"
" is displayed ... Why?
Setting cannot be made during operation. Turn the start switch (
, STF or STR) OFF.
If
is pressed before pressing
, the easy setting mode is terminated and the display goes back to the monitor
display. If the easy setting mode is terminated while
Pr. 79
= "0 (initial setting)," the operation mode switches between the PU
operation mode and the External operation mode. Check the operation mode.
Reset can be made with
.
The priorities of the speed commands when
Pr. 79
= "3" are "Multi-speed operation (RL/RM/RH/REX) > PID control (X14) >
terminal 4 analog input (AU) > digital input from the operation panel".
Blinking
Blinking
Blinking
Operation Panel Indication
Operation Mode
Start command
Speed command
External
(STF, STR)
Analog
voltage input
External
(STF, STR)
Analog
voltage input
Blinking
Blinking
Blinking
Blinking
Blinking
Blinking
Blinking
Blinking