Wiring
Control circuit specifications
FR-D700 SC EC
3 - 29
Using an external power supply
●
Sink logic type
Use terminal PC as a common terminal to prevent a malfunction caused by undesirable
current. Do not connect terminal SD of the inverter with terminal 0V of the external power
supply.
(When using terminals PC-SD as a 24V DC power supply, do not install a power supply in
parallel in the outside of the inverter. Doing so may cause a malfunction due to undesirable
current.)
●
Source logic type
When using an external power supply for transistor output, use terminal SD as a common
to prevent misoperation caused by undesirable current.
Fig. 3-19:
Using an external power supply in connection
with the outputs of a PLC (sink logic type)
I001030E
Fig. 3-20:
Using an external power supply in connection
with the outputs of a PLC (source logic type)
I001031E
AY40
Inverter
Current
AY80
Inverter
Current