18
External
: Control by signal from external terminal is only valid.
NET
: Control from network
is only valid.
Combined
: Control from both external terminal and network is valid.
—
: Control from both external terminal and network is invalid.
*1 When "7" (PU operation interlock function) is set in Pr. 79 "operation mode selection", only the external terminal is
made valid independently of the Pr. 338 and Pr. 339 settings, since this function is also used by terminal MRS.
Se
le
ct
iv
e f
unc
ti
o
n
s
Pr
. 18
0 t
o
Pr
. 18
3 set
ti
ngs
0
Low-speed operation command/
Remote setting clear (RL)
NET
External
NET
External
Pr. 59
≠
"0":
Remote
setting
1
Middle-speed operation command/
Remote setting deceleration (RM)
NET
External
NET
External
2
High-speed operation command/
Remote setting acceleration (RH)
NET
External
NET
External
3 Second function selection (RT)
NET
NET
External
External
4 Current input selection (AU)
—
Combined
—
Combined
5 Start self-holding selection (STOP)
—
—
External
External
6 Output shut-off (MRS)
Combined
Combined
External
External
*1
7 External thermal relay input (OH)
External
External
External
External
8 15-speed selection (REX)
NET
External
NET
External
Pr. 59 = 0
16
PU operation-external (network)
operation switching (X16)
External
External
External
External
18 Magnetic flux-V/F switching (X18)
NET
NET
External
External
Control
location
selection
Pr. 338 "operation control
command source"
0: NET
0: NET
1: External 1: External
Remarks
Pr. 339 "speed command source"
0: NET
1: External
0: NET
1: External