31
Profibus Device Data
24V_Pins
0
24V power supply for maintenance device connection is not
used.
Freeze_Mode_supp
1
Freeze mode supported.
Sync_Mode_supp
1
Synchronous mode supported.
Auto_Baud_supp
1
Automatic baud rate detection support
Set_Slave_Add_supp
0
Slave address is not set.
Min_Slave_Intervall
1
100 µs interval between 2 polling cycles
Modular_Station
1
Modular device specified.
Max_Module
1
Maximum number of modules: 1
Max_Input_Len
28
Input data: Maximum 28 bytes
Max_output_Len
28
Output data: Maximum 28 bytes
Max_Data_Len
56
Input and output data: Maximum 28 + 28 = 56 bytes
Fail_Safe
0
Failsafe non-support
Max_Diag_Data_Len
6
Diagnostic data of 6 bytes secured (no external diagnosis)
Slave_Family
1
Drives defined as function class (Main Family)
PrmText
1
Text selection 1 registration
Text(0)
"No byte swapping"
If Bit 0 = 0, "No byte swapping"
Text(1)
"Byte swapping"
If Bit 0 = 1, "Byte swapping"
EndPrmText
ExtUserPrmData
1 "Byte swapping"
Byte swapping selection 1 registration on text base
Bit(0) 0 0-1
Bit 0 = default 0, range 0 to 1
Prm_Text_Ref
1
Text selection 1 is used.
EndExtUserPrmData
Max_User_Prm_Data_Len
2
User parameter of 2 bytes secured
Ext_User_Prm_Data_Const(0) 01
H
Initial value of user parameter's 1 byte
Ext_User_Prm_Data_Const(1) 00
H
Initial value of user parameter's 2 byte
Parameter
Value
Description*1