45
Profibus PROFILES—PPO Non Support Specification
7.1 ID definitions
* Command request
:Message from the master to the slave
Command response :Message from the slave to the master
7.2 Buffer memory map
The following shows the buffer memory map of the E5NP Profibus profiles.
ID
Description
PKW
PKE
PNU number (PNU) and task or response Id (AK)
IND
Index number
PWE1
Not used and must be set to 0
PWE2
Parameter value
PZD
ZSW1
Bits 0 to 7: Inverter Status (command response)
Bits 8 to 14: Command Count (command request/response)
HIW
Reserved area for extension
1Word 2Word 3Word 4Word 5Word 6Word
PKE
IND
PWE
ZSW1
HIW
E5NP
Module
type