62
PARAMETER DEFINITIONS—PPO Non Support Specification
(2) Inverter status/operation command
The inverter status can be monitored and operation command can be given from the master.
IND
PNU
Item
0100
H
A
H
Inverter status
Refer to page 50.
Operation command
*1 These are factory-set signals. Input signals can be changed by input terminal function
selection (Pr. 180 to Pr. 183).
Name
Bit
Description
-
0
Reserved (0 is set)
STF terminal
1
0: STF-OFF 1: STF-ON (forward rotation command)
STR terminal
2
0: STR-OFF 1: STR-ON (reverse rotation command)
RH terminal
3
0: RH-OFF
1: RH-ON (high-speed operation command)*1
RM terminal
4
0: RM-OFF 1: RM-ON (middle-speed operation command)*1
RL terminal
5
0: RL-OFF
1: RL-ON (low-speed operation command)*1
-
6 to 9
Not used (0 is set)
MRS terminal
10
0: OFF
1: ON (Output shutoff)*1
-
11 to 15 Not used (0 is set)