67
PARAMETER DEFINITIONS—PPO Non Support Specification
9.3.2 Pr. 900 and later-frequency parameter area (IND = 0300
H
)
The following parameters can be set with IND=0300H.
9.3.3 Pr. 900 and later-% parameter area (IND = 0400
H
)
The following parameters can be set with IND=0400
H
.
Parameter
Number
IND
PNU
Name
Minimum
Setting
Increments
Setting Range
Decimal
Hexadeci-
mal
902
0300
H
149
H
Frequency setting voltage bias (frequency)
0.01Hz
0 to 60
0 to 1770
903
0300
H
14A
H
Frequency setting voltage gain (frequency)
0.01Hz
1 to 400
64 to 9C40
904
0300
H
14B
H
Frequency setting current bias (frequency)
0.01Hz
0 to 60
0 to 1770
905
0300
H
14C
H
Frequency setting current gain (frequency)
0.01Hz
1 to 400
64 to 9C40
Parameter
Number
IND
PNU
Name
Minimum Setting
Increments
902
0400
H
2
H
Frequency setting voltage bias (%)
0.1%
903
0400
H
3
H
Frequency setting voltage gain (%)
0.1%
904
0400
H
4
H
Frequency setting current bias (%)
0.1%
905
0400
H
5
H
Frequency setting current gain (%)
0.1%